Implantable Electrode Lead, Model 030-439

by Telectronics, Inc.

510(k) K864618

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK864618 Date21 May 1987ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is an Implantable Electrode Lead, classified as a Permanent Pacemaker Electrode under regulatory nomenclature. It is designed for use in cardiac pacing systems to deliver electrical impulses to the heart, facilitating proper heart rhythm regulation in patients with bradycardia or other conduction disorders. The lead is intended for subcutaneous or intracardiac implantation to establish electrical continuity between a pacemaker generator and cardiac tissue.

The Model 030-439 is supplied sterile and intended for single-use implantation. It is regulated under FDA 510(k) clearance (K864618) and falls under Device Type DTB, classified as Class III for high-risk medical devices. Compliance with 21 CFR 870.3680 ensures adherence to manufacturing and performance standards. Storage requires protection from moisture and mechanical damage prior to use, as specified in the device documentation.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical purpose of the Model 030-439 Implantable Electrode Lead, and how is it positioned within the body during use?

    The Model 030-439 Implantable Electrode Lead is designed to deliver electrical impulses to the heart as part of a cardiac pacing system. It is intended for subcutaneous or intracardiac implantation to establish electrical continuity between a pacemaker generator and cardiac tissue, helping regulate heart rhythm in patients with bradycardia or conduction disorders.

  • Is the Model 030-439 lead intended for single-use or reusable applications, and how should it be stored before use?

    The Model 030-439 is explicitly intended for single-use implantation only. Prior to use, it must be stored in a way that protects it from moisture and mechanical damage, as outlined in the device documentation.

  • What regulatory pathway was followed for FDA clearance of this device, and which advisory committee was involved?

    The Model 030-439 received FDA clearance through a Traditional 510(k) pathway (K864618) with a decision of *Substantially Equivalent*. The review was conducted by the Cardiovascular (CV) Advisory Committee, reflecting its classification as a high-risk Class III device under regulatory nomenclature.

  • How is the sterility of the Model 030-439 lead ensured, and what does this imply for clinical handling?

    The lead is supplied sterile, meaning it is pre-sterilized and packaged to maintain sterility until use. This ensures a clean surgical field during implantation, reducing infection risks. Clinicians should follow manufacturer guidelines for opening the sterile packaging and handling to preserve sterility.