Implantable Electrode Lead, Model 030-446

by Telectronics, Inc.

510(k) K874664

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK874664 Date31 May 1988ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, a type of implantable electrode lead designed to facilitate cardiac pacing by transmitting electrical impulses to the heart. It is intended for use in conjunction with pacemaker systems to regulate abnormal heart rhythms by delivering timed electrical stimuli to the myocardium.

The Model 030-446 is supplied sterile and intended for single-use implantation. It is classified as a Class 3 device under FDA regulations (870.3680) and was cleared via a Traditional 510(k) pathway (K874664) in 1988. The lead is intended for use in cardiovascular applications and must be implanted surgically, adhering to sterile procedures. No additional regulatory status beyond the stated FDA clearance is implied.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the Model 030-446 Implantable Electrode Lead, and how does it function within a pacemaker system?

    The Model 030-446 is designed as a permanent pacemaker electrode lead to regulate abnormal heart rhythms by delivering timed electrical impulses to the heart muscle (myocardium). It works in conjunction with a pacemaker system, transmitting electrical signals directly to the heart to maintain proper pacing when the heart’s natural rhythm is disrupted.

  • Is this device intended for reuse, or is it meant to be implanted once and discarded?

    The Model 030-446 is sterile and intended for single-use only. After implantation, it should not be reused, as this could compromise patient safety and sterility.

  • What type of regulatory clearance does this device hold, and how was it approved by the FDA?

    The Model 030-446 was cleared by the FDA under a Traditional 510(k) pathway (K874664) in 1988. It is classified as a Class 3 device under FDA regulations (870.3680), meaning it was determined to be substantially equivalent to a legally marketed predicate device at the time of clearance.

  • How should this device be stored before use, given its sterile packaging?

    Since the Model 030-446 is supplied sterile, it must be stored in its original, unopened packaging until ready for use. The packaging should be kept dry, protected from contamination, and away from extreme temperatures or direct sunlight to maintain sterility.