Implantable Programmable Cardiac Pulse
510(k) K810603
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK810603 | Date14 Apr 1981 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is an Implantable Pacemaker Pulse-Generator, classified as a Class III medical device under FDA regulations. It is designed to regulate heart rhythm by delivering electrical impulses to the heart muscle when the natural pacemaker fails to do so, thereby treating bradycardia or other cardiac conduction disorders.
The device is implanted subcutaneously and is intended for single-use after initial programming. It is regulated under FDA 510(k) clearance (K810603) and falls under the Implantable Pacemaker Pulse-Generator nomenclature (DXY, regulation number 870.3610). Sterility and MRI safety are critical considerations, as outlined in the device specifications, and it must be handled in sterile conditions prior to implantation.
Other devices from Telectronics, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of this implantable device and what types of patients would benefit from it?
This device is an Implantable Pacemaker Pulse-Generator designed to regulate heart rhythm by delivering electrical impulses when the heart’s natural pacemaker fails. It treats bradycardia (slow heart rate) and other cardiac conduction disorders, ensuring consistent contractions in patients whose hearts do not beat adequately on their own. Clinicians typically recommend it for patients with persistent slow heart rhythms or conduction blockages.
Is this device intended for single-use or can it be reused after implantation?
The device is explicitly designed for single-use after initial programming. Once implanted, it is not intended to be removed or reused, aligning with standard practice for pacemaker pulse-generators to avoid infection or reliability risks. Sterility is critical prior to implantation, as noted in the specifications.
What storage or handling precautions must be taken before implantation?
This device must be handled in sterile conditions before implantation, as sterility is a critical consideration per the manufacturer’s specifications. It should be stored according to the provided instructions to maintain its integrity and functionality until use, typically in a sealed, sterile packaging until opened for surgical preparation.
How was this device’s regulatory pathway determined, and what does that mean for clinicians?
The device was cleared via a Traditional 510(k) pathway (K810603) and classified as a Class III medical device under FDA regulations, with a substantially equivalent determination by the Cardiovascular (CV) Advisory Committee. Clinicians can rely on this clearance as evidence of safety and performance equivalence to a predicate device, ensuring it meets FDA standards for pacemaker pulse-generators.