Implantable Programmable Cardiac Pulse Generators
by Telectronics, Inc. 3 variants
510(k) K872766
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK872766 | Date4 Nov 1987 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is an Implantable Pacemaker Pulse-Generator (product code DXY), classified as a Class III medical device. It is designed to generate and regulate electrical impulses to stimulate the heart muscle, ensuring proper cardiac rhythm in patients with bradycardia or other conduction disorders. The device is programmable, allowing for adjustments to pacing parameters such as rate and output, tailored to individual patient needs.
Implantable Programmable Cardiac Pulse Generators are surgically implanted beneath the skin, typically in the chest region, and connected to leads that interface with the heart. They are intended for single-use implantation and are not reusable. The device is regulated under FDA 510(k) clearance (K872766) and falls under the Cardiovascular advisory committee review. No specific MRI safety information or sterility details are provided in the data, but compliance with FDA Premarket Approval (PMA) requirements applies for Class III devices.
Other devices from Telectronics, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Implantable Programmable Cardiac Pulse Generator from Telectronics, Inc.?
This device is designed to generate and regulate electrical impulses to stimulate the heart muscle, helping maintain proper cardiac rhythm in patients with bradycardia or conduction disorders. Its programmability allows for adjustments to pacing parameters like rate and output, tailored to individual patient needs.
How is the Implantable Programmable Cardiac Pulse Generator supplied and intended for use?
The device is surgically implanted beneath the skin, typically in the chest region, and connected to leads that interface with the heart. It is intended for single-use implantation only and is not designed for reuse. The device is classified as a Class III medical device under FDA regulations.
What regulatory pathway was followed for FDA clearance of this device?
The Implantable Programmable Cardiac Pulse Generator received FDA 510(k) clearance (K872766) under the Traditional 510(k) Review pathway, with a decision of *Substantially Equivalent* (SESE). It falls under the Cardiovascular (CV) Advisory Committee and is regulated under product code DXY.
Are there multiple models or variations of this device listed in regulatory records?
Yes, the data includes multiple FEI numbers (e.g., 3002807576, 2017865, etc.) and registration numbers, suggesting there may be different models or variations of the Implantable Programmable Cardiac Pulse Generator. These identifiers correspond to specific submissions under the same product code (DXY).
What type of facility or specialty is this device associated with in clinical practice?
This device is categorized under Cardiovascular medical specialty, meaning it is primarily used in clinical settings such as cardiology departments, electrophysiology labs, or hospitals specializing in cardiac care. Its function directly supports patients with heart rhythm disorders.