Skip to content

Implantable Programmable Pulse Gener

by Telectronics, Inc.

510(k) K840737

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK840737 Date16 May 1984ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is an Implantable Pacemaker Pulse-Generator, a Class III medical device designed to regulate cardiac rhythm by generating and delivering electrical impulses to the heart. It is intended for patients with bradycardia or other conduction disorders requiring chronic pacing support, providing programmable pacing parameters to match individual patient needs.

The device is supplied sterile and intended for single-use implantation, adhering to FDA 510(k) clearance (K840737) under regulation 870.3610. It is classified under the product code DXY and reviewed by the Cardiovascular Advisory Committee. No MRI safety or reusable specifications are noted in the regulatory data.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of this implantable device, and who is it designed for?

    This device is an Implantable Pacemaker Pulse-Generator, designed to regulate abnormal heart rhythms (bradycardia or conduction disorders) by delivering programmable electrical impulses to the heart. It is intended for patients requiring chronic pacing support, allowing adjustments to pacing parameters tailored to individual patient needs.

  • Is this device reusable, or is it meant for single-use after implantation?

    The device is intended for single-use implantation only, as explicitly stated in the regulatory data. It is supplied sterile and not designed for reuse.

  • How is this device classified, and what regulatory pathway was followed for its approval?

    This is a Class III medical device under FDA regulations, reviewed by the Cardiovascular Advisory Committee and cleared via a Traditional 510(k) pathway (K840737). It falls under product code DXY and regulation 870.3610, with a decision of *Substantially Equivalent* (SESE).

  • Does this device have any special handling requirements, such as storage or sterility considerations?

    The device is supplied sterile and must be handled under aseptic conditions prior to implantation. Since it is single-use, proper storage in a clean, dry environment (as per manufacturer guidelines) is recommended to maintain sterility until use.

  • Are there any known limitations regarding compatibility with other medical procedures, such as MRI?

    The regulatory data does not specify MRI safety for this device, meaning its compatibility with MRI procedures is not confirmed or recommended. Patients should avoid MRI scans unless explicitly cleared by the device manufacturer or a cardiologist.