Ref P04 N0041

In2Bones (P04 N0041) is an orthopaedic bur (EU MDR Class I; FDA Class I; FDA product code LXH, Orthopedic manual surgical instrument) made by In2Bones, USA, registered in EUDAMED on 29 Jan 2026 (Basic UDI-DI 08101755051447), cleared under FDA 510(k) K163293 on 5 May 2017 and listed in FDA GUDID since 12 Dec 2024 (UDI-DI 00810021864914), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K163293

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number08101755051447 Basic UDI-DI 00810021864914UDI-DIDate29 Jan 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00810021864914 UDI-DI Date12 Dec 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK163293 Date5 May 2017DecidedStatusActive

Official records

From the FDA record

Device description
BENDING IRON, NON-STERILE
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 08101755051447 registered 29 Jan 2026 Active
  • FDA 510(k) K163293 decided 5 May 2017 Active
  • FDA GUDID UDI-DI 00810021864914 listed 12 Dec 2024 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2879-2018 FDA Class II initiated 16 Jul 2018 on shared 510(k) K163293
    • Terminated Z-2880-2018 FDA Class II initiated 16 Jul 2018 on shared 510(k) K163293

    CoLink(TM) Lapidus Plate +2mm Right and Left, were laser marked incorrectly. In these lots, right plates were laser marked as left plates and the left plates were laser marked as right plates.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K163293
  2. Recall initiated FDA recalls Z-2879-2018
  3. Recall initiated FDA recalls Z-2880-2018
  4. Listed FDA GUDID 00810021864914
  5. Registered EUDAMED 08101755051447

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Orthopaedic bur, reusable
Device name
Non-patient-contacting Class I instruments, Non-Active
Model / Ref / Catalog
P04 N0041
Primary DI / UDI-DI
00810021864914
Basic UDI-DI
08101755051447
510(k) Number
FDA product code
LXH
EMDN code
L0999 Orthopaedic and traumatological surgery instruments, reusable - other
GMDN term
Orthopaedic bur, reusable
Device class
Class I
Regulation number
888.4540
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Conditional

Manufacturer details

EUDAMED SRN
US-MF-000023092
Authorised representative
Conmed Europe BV BE-AR-000035662

Similar devices in this category

Other devices filed under ORTHOPAEDIC AND TRAUMATOLOGICAL SURGERY INSTRUMENTS, REUSABLE - OTHER.

Other devices from In2Bones, USA

See all devices from In2Bones, USA →

Properties

  • Sterilise before use
  • Reusable
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (20, all answered No)