  "format": "devicerts.device.v1",
  "cite_as": "Inceptiv™ 977119, Medtronic, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/inceptiv-977119 (data as of 2026-11-24).",
  "source": {
    "canonical_url": "https://devicerts.com/devices/inceptiv-977119",
    "json_url": "https://devicerts.com/devices/inceptiv-977119.json",
    "markdown_url": "https://devicerts.com/devices/inceptiv-977119.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "FDA GUDID (AccessGUDID)",
        "url": "https://accessgudid.nlm.nih.gov/"
      },
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      },
      {
        "registry": "FDA recalls",
        "url": "https://open.fda.gov/apis/device/recall/"
      }
    ],
    "registry_records_last_synced": "2026-10-25",
    "status_as_of": "2026-11-24",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/devices/inceptiv-977119",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "device": {
    "name": "Inceptiv™ 977119",
    "registry_name": "Inceptiv™ 977119",
    "url": "https://devicerts.com/devices/inceptiv-977119",
    "manufacturer": {
      "name": "Medtronic, Inc.",
      "url": "https://devicerts.com/manufacturers/medtronic-inc",
      "country": "United States",
      "country_basis": null,
      "fda_registration_country": null
    },
    "status": {
      "state": "active",
      "label": "Active",
      "detail": "European Union and United States"
    },
    "classification": [
      {
        "class": "Class III",
        "system": "EU MDR / US FDA"
      }
    ],
    "identifiers": [
      {
        "label": "Primary DI / UDI-DI",
        "values": [
          {
            "value": "00763000850159",
            "registries": [
              "EUDAMED"
            ]
          },
          {
            "value": "00763000957773",
            "registries": [
              "EUDAMED"
            ]
          },
          {
            "value": "00763000984694",
            "registries": [
              "EUDAMED"
            ]
          },
          {
            "value": "00763000984700",
            "registries": [
              "EUDAMED"
            ]
          },
          {
            "value": "00763000540302",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      },
      {
        "label": "Basic UDI-DI",
        "values": [
          {
            "value": "0763000B000020674",
            "registries": [
              "EUDAMED"
            ]
          }
        ]
      },
      {
        "label": "PMA number",
        "values": [
          {
            "value": "P840001",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      }
    ],
    "product_codes": [
      "LGW",
      "QRB"
    ],
    "emdn": [
      {
        "code": "J02020201",
        "term": "FULLY IMPLANTABLE SPINAL NEUROSTIMULATORS, RECHARGEABLE"
      }
    ],
    "gmdn": [
      {
        "code": "64970",
        "term": "Spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator, implantable"
      }
    ],
    "description": null,
    "noindex": false
  },
  "authorizations": [
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/MDR",
      "number": "0763000B000020674",
      "number_label": "Basic UDI-DI",
      "device_udi_di": null,
      "date": "2026-07-14",
      "date_kind": "registered",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/MDR",
      "number": "G70 039709 1443",
      "number_label": null,
      "device_udi_di": null,
      "date": "2026-06-15",
      "date_kind": "issued",
      "decision_code": null,
      "expires": "2028-08-13",
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "GUDID listing",
      "number": "00763000850159",
      "number_label": "UDI-DI",
      "device_udi_di": null,
      "date": "2024-05-05",
      "date_kind": "listed",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Listed",
      "status_note": "GUDID: in commercial distribution",
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "FDA PMA",
      "number": "P840001",
      "number_label": null,
      "device_udi_di": null,
      "date": "1984-11-30",
      "date_kind": "decision",
      "decision_code": "APPR",
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": true
    }
  ],
  "no_longer_listed_by": [],
  "certificates": [
    {
      "number": "G70 039709 1443",
      "type": "Technical documentation",
      "legislation": "MDR",
      "notified_body": "TÜV SÜD Product Service GmbH",
      "issued": "2026-06-15",
      "expires": "2028-08-13",
      "status": "supplemented",
      "no_longer_listed": false
    }
  ],
  "recalls": [
    {
      "number": "Z-0372-2025",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-09-18",
      "reason": "The Wireless Rechargers in the kits may be unable to enter a recharging session upon first use.",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-1691-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-03-28",
      "reason": "inability to reprogram one device",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-0780-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-12-19",
      "reason": "Medtronic has discovered an instance in which the Intellis A710 Clinician Programmer Application (CP App) could no longer establish a session with the Implantable Neurostimulator (INS) which resulted in the inability for the clinician to adjust stimulation parameters. In the event of this issue, the patient may receive inadequate or excessive therapy and experience non-optimal pain relief.",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-2159-2021",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2021-07-09",
      "reason": "Specific PINs of the Vectris SureScan MRI lead kits contain the incorrect lead electrode spacing information printed on the shelf box and the sterile pack labeling.",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-1926-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-05-03",
      "reason": "Loss of therapy during recharging of device. Reportedly, a charging session was terminated prior to obtaining recharge threshold voltage of 3.615, which triggered rapid battery depletion state. As a result, the device depleted to 1.925 volts in one to two days rather than the typical 30 days. Insufficient coupling between recharger and device during recharge session was found to be key factor.",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-1147-2015",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2015-01-09",
      "reason": "Current labeling indicates that cycling improves device longevity in every programming scenario. However, enabling cycling at certain parameter settings may decrease the device battery longevity. With cycling enabled, longevity estimate displayed on the Model 8840Programmer may be inaccurate.",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-1524-2014",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2014-02-27",
      "reason": "Medtronic neurostimulators (used with pain and deep brain stimulation therapy) have a cycling feature that, when enabled, allows stimulation output to be toggled on and off based on the programmed settings.  The use of this feature is determined by the physician and set using the clinician programmer.  \nCurrent labeling indicates the use of cycling improves device longevity and recharge interval",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-0278-2014",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2013-09-30",
      "reason": "Medtronic notified customers regarding Loss of Stimulation of specific Implantable Neuro-Stimulators under the following specific conditions:  Switching between groups with Multiple programs or creating program groups.  Therapy can be restored with the Physician Recharge mode (RPM) of the Implantable Neurostimulator Recharger (INSR).",
      "applies": "this device",
      "via": "P840001"
    },
    {
      "number": "Z-1536-06",
      "classification": "",
      "status": "terminated",
      "initiated": "2006-08-02",
      "reason": "Model 3777 Standard Octad Lead (Lot V009545) and Model 3778 Compact Octad Lead (Lot V009546) were mispackaged.  The result of this error is that lead kits labeled 3777 lot V009545 may contain a 3778 compact-spaced lead, while those labeled 3778 lot V009546 may contain a 3777 standard-spaced lead. The result of this error is an overall increase or decrease of 14 mm in the electrode coverage.",
      "applies": "this device",
      "via": "P840001"
    }
  ],
  "eu_market_availability": null,
  "properties": [
    {
      "group": "Identity",
      "fields": [
        {
          "label": "Trade name",
          "values": [
            {
              "value": "Inceptiv™",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Generic name",
          "values": [
            {
              "value": "Spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator, implantable",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Device name",
          "values": [
            {
              "value": "Implantable Spinal Neurostimulator",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Model / reference",
          "values": [
            {
              "value": "977119",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Identifiers",
      "fields": [
        {
          "label": "Primary DI / UDI-DI",
          "values": [
            {
              "value": "00763000850159",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "00763000957773",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "00763000984694",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "00763000984700",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "00763000540302",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Basic UDI-DI",
          "values": [
            {
              "value": "0763000B000020674",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "PMA number",
          "values": [
            {
              "value": "P840001",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "FDA product code",
          "values": [
            {
              "value": "LGW",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            },
            {
              "value": "QRB",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EMDN code",
          "values": [
            {
              "value": "J02020201",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GMDN term",
          "values": [
            {
              "value": "Spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator, implantable",
              "code": "64970",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Classification",
      "fields": [
        {
          "label": "Device class",
          "values": [
            {
              "value": "Class III",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EU registration type",
          "values": [
            {
              "value": "Standard device",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "EU market of registration",
          "values": [
            {
              "value": "Netherlands",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GUDID distribution status",
          "values": [
            {
              "value": "In Commercial Distribution",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Clinical & Handling",
      "fields": [
        {
          "label": "MRI safety",
          "values": [
            {
              "value": "MR Conditional",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Properties",
      "fields": [
        {
          "label": "Supplied sterile",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Single use",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Implantable",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Measuring function",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Prescription use",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Serial number",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Sterilise before use",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Reusable",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains latex",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Reprocessed single-use device",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Incorporates a substance derived from human blood or plasma",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains human tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains animal tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains endocrine-disrupting substances",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Administering medicine",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Incorporates a medicinal substance",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Over-the-counter",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Convenience kit",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Combination product",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "HCT/P",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Premarket exempt",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Lot / batch number",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Expiration date",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Manufacturing date",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    }
  ]
}