Skip to content

Infant Flexiwrap Sensor

by Nonin Medical, Inc.

Ref 4774-000Model MODEL 8008JFW, INFANT FLEXIWRAP SENSOR DISP

Infant Flexiwrap Sensor (4774-000) is a dressing-fixation skin adhesive tape (EU MDD Class IIb; FDA Class II; FDA product code DQA, Oximeter) made by Nonin Medical, Inc., registered in EUDAMED on 11 Dec 2024 (Basic UDI-DI B-00833166000641) and listed in FDA GUDID since 3 Sep 2016 (UDI-DI 00833166000641), active as of 22 Oct 2026.

Active European Union. Also listed in GUDID (US).

CE MDD

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00833166000641 Basic UDI-DI 00833166000641UDI-DIDate11 Dec 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00833166000641 UDI-DI Date3 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Flexiwrap
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI B-00833166000641 registered 11 Dec 2024 Active
  • FDA GUDID UDI-DI 00833166000641 listed 3 Sep 2016 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 00833166000641
  2. Registered EUDAMED B-00833166000641

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Infant Flexiwrap Sensor EUDAMED
Nonin GUDID
Generic name
Dressing-fixation skin adhesive tape, non-silicone
Model / reference
MODEL 8008JFW EUDAMED
INFANT FLEXIWRAP SENSOR DISP EUDAMED
4774-000 EUDAMED
8008JFW GUDID
Primary DI / UDI-DI
00833166000641
Basic UDI-DI
B-00833166000641
FDA product code
DQA
EMDN code
C900301 Pulse oximeter sensors
GMDN term
Dressing-fixation skin adhesive tape, non-silicone
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
870.2700
System or procedure pack
Procedure pack which is a device in itself
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
MODEL 8008JFW, INFANT FLEXIWRAP SENSOR DISP
4774-000
GUDID
8008JFW
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000008228
Authorised representative
MPS Medical Product Service GmbH DE-AR-000005009

Similar devices in this category

Other devices filed under PULSE OXIMETER SENSORS.

Other devices from Nonin Medical, Inc.

See all devices from Nonin Medical, Inc. →

Properties

  • Single use
  • Measuring function
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)