Skip to content

InfusionCath

by Id, LLC

510(k) K041517

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 5 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 5 Oct 2026. What this means

Regulatory status

as of registry sync 5 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK041517 Date5 Aug 2004ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 5 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
QEY
Device Class
Class II
Regulation
21 CFR Part 870.5150
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The InfusionCath is a Mechanical Thrombolysis Catheter, designed to temporarily occlude a vessel while delivering physician-specified fluids, such as thrombolytics. It features a distal occlusion balloon, a catheter body with elution holes, and a proximal trifurcated Luer connection hub. This device is intended for use in peripheral vascular applications to facilitate localized treatment delivery.

The InfusionCath is supplied as a single-use device and is regulated under FDA 510(k) clearance (K041517) with a classification of Class II (QEY). It is intended for use in cardiovascular procedures and must be handled in accordance with sterile medical device protocols. No MRI safety information is specified, and storage conditions align with standard sterile catheter requirements. Authorizations are limited to the stated FDA 510(k) clearance.

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the InfusionCath designed for in medical procedures?

    The InfusionCath is a mechanical thrombolysis catheter specifically designed to temporarily occlude a blood vessel while allowing physician-specified fluids, such as thrombolytics, to be delivered locally. This facilitates targeted treatment in peripheral vascular applications, helping to break down clots in controlled areas of the circulatory system.

  • How is the InfusionCath supplied and intended for use?

    The InfusionCath is supplied as a single-use device, meaning it is intended for one-time use only and must not be reused. This ensures sterility and safety for each procedure. It is regulated under FDA 510(k) clearance (K041517) and must be handled according to sterile medical device protocols to maintain its integrity and effectiveness.

  • Does the InfusionCath have any special features that distinguish it?

    Yes, the InfusionCath features a distal occlusion balloon to block blood flow in the targeted vessel, a catheter body with elution holes for precise fluid delivery, and a proximal trifurcated Luer connection hub for secure attachment to infusion systems. These design elements enable localized thrombolytic treatment while maintaining vessel occlusion.

  • What storage conditions should be followed for the InfusionCath?

    The InfusionCath should be stored under standard sterile catheter conditions, as with other sterile medical devices. This typically includes keeping it in its original packaging, away from direct sunlight, extreme temperatures, and contamination sources. Always follow manufacturer guidelines to ensure sterility and functionality before use.

  • Is there any specific safety information regarding MRI compatibility for the InfusionCath?

    The provided data does not specify any MRI safety information for the InfusionCath. If MRI imaging is required after or during use, clinicians should consult the device’s labeling or manufacturer for guidance to avoid potential risks associated with magnetic fields.