Infx-8000F (Infinix Csi and Infinix Dpi)

by Toshiba America Medical Systems, In.C

510(k) K081624

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK081624 Date23 Jun 2008ClearedStatusActive

Recalls

8 recalls · 3 ongoing · FDA

    • Ongoing Z-1176-2021 FDA Class II initiated 5 Feb 2021

    The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.

    • Ongoing Z-1271-2021 FDA Class II initiated 8 Dec 2020

    System table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose.

    • Ongoing Z-2327-2020 FDA Class II initiated 3 Mar 2020

    Bolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting.

    • Terminated Z-0360-2020 FDA Class II initiated 8 Feb 2019

    Table tilts without operator involvement as a result of liquid spilling into tilt console triggering a short circuit.

    • Terminated Z-0842-2018 FDA Class II initiated 29 Dec 2017 on shared 510(k) K081624

    During an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error.

    • Terminated Z-0994-2013 FDA Class II initiated 8 Nov 2012

    Lost and incorrect images. When using the "F-Rec" fluoroscopy image acquisition recording option in the "manual mode" an infrequent software error may cause images from another study to be displayed on the monitor. The acquired images may be lost requiring additional image acquisitions to be performed.

    • Terminated Z-0331-2012 FDA Unclassified (pre-2012) initiated 3 Oct 2011

    The recall was initiated because Toshiba has confirmed that during patient transfer from a gurney to the catherization table, the tabletop may rotate unexpectedly when sufficient force is applied to the tabletop. The result of the tabletop rotating unexpectedly is the patient being tranferred may fall from the tabletop.

    • Terminated Z-0005-2009 FDA Unclassified (pre-2012) initiated 29 Sep 2008

    Audible signal is not available at all times when using the HLC fluoroscopy mode. Special means of activation are not designed in for selection of High Level Controls, as required by regulation.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MQB
Device Class
Class II
Regulation
21 CFR Part 892.1680
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent