Ingenia 1.5T CX and Ingenia 3.0T CX R5.3
by Philips Medical Systems Nederland B.V.
510(k) K162931
Active
Valid until
Not listed
FDA recalls
9 ongoingTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE 510(k) | NumberK162931 | Date6 Jan 2017 | StatusActive |
| European Union | CE/MDR EUDAMED | Number— | Date— | StatusActive |
Recalls
-
- Ongoing Z-1789-2025
- Ongoing Z-1788-2025
- Ongoing Z-1791-2025
- Ongoing Z-1790-2025
Potential for alignment errors in the cross reference line functionality when reviewing images generated with the MobiView application.
-
- Ongoing Z-0389-2024
- Ongoing Z-0390-2024
- Ongoing Z-0393-2024
- Ongoing Z-0394-2024
- Ongoing Z-0392-2024
Potential component failure in the Gradient Coil could product smoke and/or fire.
-
- Completed Z-2420-2021
- Completed Z-2415-2021
- Completed Z-2414-2021
- Completed Z-2421-2021
- Completed Z-2412-2021
When using manual mode, the tabletop may not completely move in or out and result in potential delay in patient evacuation from the bore, which could result in a delay of treatment
-
- Terminated Z-2341-2021
- Terminated Z-2345-2021
Pressure relief valve 42 psi installed in the magnet assembly instead of a 3.75 psi valve, may result in release of helium gas and cause injury
-
- Terminated Z-0901-2019
- Terminated Z-0902-2019
- Terminated Z-0904-2019
There is a potential for the ceiling speaker(s) to fall from their position and be pulled to the MR system by the magnetic field.
-
- Terminated Z-1436-2018
- Terminated Z-1437-2018
Potential risk for helium gas inside the MR examination room during a magnet quench
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- 510(k) Number
- FDA Product Code
- LNH
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1000
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 are magnetic resonance imaging (MRI) systems designed for high-field strength and advanced diagnostic imaging. These devices utilize nuclear magnetic resonance technology to generate detailed images of internal body structures, enabling precise evaluation for radiology applications in clinical settings.
These MRI systems are intended for use in radiology departments and are supplied as reusable medical equipment. They are not classified as single-use devices and require proper maintenance and calibration. The Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 comply with FDA 510(k) and MDR authorizations, adhering to regulatory standards for nuclear magnetic resonance imaging systems. They are classified under device class II and are intended for use in environments where MRI safety protocols must be strictly followed.
Other devices from Philips Medical Systems Nederland B.V.
See all devices from Philips Medical Systems Nederland B.V. →
Questions
AI-generated answers, 18 Sep 2026
What types of clinical environments are the Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems intended for, and why?
The Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems are specifically designed for use in radiology departments. This is because they utilize nuclear magnetic resonance technology to generate detailed images of internal body structures, enabling precise diagnostic evaluations. The systems require strict adherence to MRI safety protocols, which are typically enforced in specialized radiology settings.
Are the Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems single-use or reusable, and what does that mean for maintenance?
The Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems are not single-use devices—they are reusable medical equipment. This means they require regular maintenance, calibration, and servicing to ensure optimal performance, safety, and compliance with regulatory standards over their operational lifespan.
What regulatory pathways have the Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems followed, and what does that imply for their use?
The Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems have been authorized through FDA 510(k) and MDR (Medical Device Regulation) pathways. This implies they meet regulatory standards for nuclear magnetic resonance imaging systems and are classified under device class II, requiring compliance with safety, performance, and quality management systems as outlined in these frameworks.
How do the Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems differ in terms of field strength, and what does that mean for imaging capabilities?
The Ingenia systems come in two field strengths: 1.5T (Tesla) and 3.0T (Tesla). Higher field strength (3.0T) generally provides superior image resolution and contrast, enabling more detailed visualization of soft tissues and smaller structures, which can be particularly useful for complex diagnostic evaluations. The 1.5T model offers a balance between image quality and accessibility, often preferred for broader clinical applications.
What should buyers or facilities consider regarding the storage and handling of the Ingenia MRI systems?
While the Ingenia 1.5T CX and Ingenia 3.0T CX R5.3 MRI systems themselves are not single-use, their components or accessories may require careful handling. The systems are designed for radiology departments, so facilities must ensure proper installation in designated MRI-safe areas, away from incompatible materials (e.g., ferromagnetic objects). Regular maintenance and adherence to manufacturer guidelines are critical to preserve performance and safety, as these systems are not intended for casual or temporary use.