Ingenia 3.0T, Ingenia 3.0T CX, Ingenia Elition and MR 7700 with Distributed Multi Nudclei
by Philips Medical Systems Nederland B.V.
510(k) K213516
Active
Valid until
No expiry
FDA recalls
45 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK213516 | Date3 Mar 2022 | StatusActive |
Recalls
-
- Ongoing Z-3311-2026
- Ongoing Z-3316-2026
- Ongoing Z-3313-2026
When exporting diffusion tensor imaging (DTI) scans from a MR system using the Enhanced MR DICOM format, the exports contain incorrect data (diffusion directions). If the Enhanced MR DICOM export is used in conjunction with third-party software for tractography (e.g. for mapping nerve fiber pathways in the brain), the software will not be able to correctly process the DTI data for reconstruction.
-
- Ongoing Z-3243-2026
- Ongoing Z-3239-2026
- Ongoing Z-3242-2026
A software issue will terminate an examination during the image reconstruction process if the scan parameters are manually adjusted such that reconstruction requirements exceed the available system memory.
-
- Ongoing Z-1969-2026
- Ongoing Z-1963-2026
The potential for stiffness value errors when a specific range of image reconstruction parameters is used in combination with Resoundant's algorithm, leading to the reconstruction voxel size settings in the default MRE scan protocol displaying too small.
-
- Ongoing Z-1213-2026
- Ongoing Z-1214-2026
The potential for stiffness value errors when viewing exported MR Elastography (MRE) stiffness maps to viewer Picture Archiving and Communication System (PACS).
-
- Ongoing Z-2207-2025
- Ongoing Z-2214-2025
The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.
-
- Ongoing Z-1805-2025
- Ongoing Z-1792-2025
Potential for alignment errors in the cross reference line functionality when reviewing images generated with the MobiView application.
-
- Ongoing Z-1782-2025
- Ongoing Z-1776-2025
- Ongoing Z-1783-2025
- Ongoing Z-1772-2025
- Ongoing Z-1770-2025
- Ongoing Z-0951-2024
The Quadrature Body Coil (QBC) seal adhesive may fail, creating sharp edges that may come in contact with patients. If the QBC seal becomes loose during the scanning process, the risk to the patient may include skin abrasions, bruises, lacerations, hair loss/entanglement, and tissue injury.
-
- Ongoing Z-3201-2024
- Ongoing Z-3193-2024
- Ongoing Z-3198-2024
- Ongoing Z-3199-2024
- Ongoing Z-3205-2024
- Ongoing Z-3202-2024
- Ongoing Z-3196-2024
- Ongoing Z-3200-2024
- Ongoing Z-3203-2024
- Ongoing Z-3194-2024
- Ongoing Z-3204-2024
- Ongoing Z-3195-2024
- Ongoing Z-3197-2024
Integrated Radio Frequency (IRF) Carrier assembly screws may come loose and protrude beyond the surface could cause the screws to interfere with other moving parts, potentially blocking the horizontal tabletop. May lead to delay in diagnosis and/or may include anxiety of a patient is left on the tabletop inside the bore for a longer duration than anticipated. movement.
-
- Ongoing Z-1570-2024
- Ongoing Z-1571-2024
- Ongoing Z-1588-2024
Patient support table floor plate may be incorrectly installed.
-
- Ongoing Z-2395-2023
- Ongoing Z-2396-2023
The system operator is able to bypass the SmokeDetector Interlock system locking mechanism after a smoke detection by power cycling the system.
-
- Ongoing Z-2399-2023
- Ongoing Z-2398-2023
During installation of the SmokeDetector Interlock, a connecting cable, between the SmokeDetector Interlock and the host PC, may not have been properly installed. This connection is used for service diagnostics and does not impact the functionality of the system and/or the SmokeDetector Interlock system.
-
- Ongoing Z-0463-2023
- Ongoing Z-0461-2023
- Ongoing Z-0462-2023
- Ongoing Z-0459-2023
- Ongoing Z-0460-2023
Gradient Coil may act as a heat source with a potential to produce smoke and/or fire.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- LNH
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1000
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Other devices from Philips Medical Systems Nederland B.V.
See all devices from Philips Medical Systems Nederland B.V. →