Inratio/INRATIO2 Test Strips

by Biosite Incorporated

510(k) K092987

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK092987 Date11 Jun 2010ClearedStatusActive

Recalls

7 recalls · FDA

    • Terminated Z-2361-2016 FDA Class I initiated 11 Jul 2016

    Alere San Diego is initiating a voluntary recall for the Alere INRatio/INRatio2 PT/INR Monitoring Systems (Test Strips and Meters). This action is being initiated as a result of patients who had a therapeutic or near-therapeutic INR with the Alere INRatio/INRatio2 PT/INR Monitoring System but a significantly higher INR (outside of therapeutic range) when performed by a central laboratory.

    • Terminated Z-2362-2016 FDA Class I initiated 11 Jul 2016

    Alere San Diego is initiating a voluntary recall for the Alere INRatio/INRatio2 PT/INR Test Strips. This action is being initiated as a result of patients who had a therapeutic or near-therapeutic INR with the Alere INRatio/INRatio2 PT/INR System but a significantly higher INR (outside of therapeutic range) when performed by a central laboratory.

  • 3 recalls, same reason

    • Terminated Z-0880-2015 FDA Class I initiated 5 Dec 2014
    • Terminated Z-0881-2015 FDA Class I initiated 5 Dec 2014
    • Terminated Z-0882-2015 FDA Class I initiated 5 Dec 2014

    In certain cases, an INRatio PT/INR Monitor system may provide an INR result that is significantly lower than a result obtained using a reference INR system (laboratory method). This issue can arise if the patient has certain medical conditions. It can also occur if the instructions in the labeling for performing the test are not followed.

    • Terminated Z-1546-2014 FDA Class I initiated 16 Apr 2014

    Test Strips may report an inaccurately low INR result. Several patients had a therapeutic or near-therapeutic INR with the Alere INRatio2 PT/INR Professional Test Strip but a significantly higher INR (outside of therapeutic range) when performed by a central laboratory.

    • Terminated Z-2661-2011 FDA Unclassified (pre-2012) initiated 28 Feb 2011

    The recall of the Triad Group alcohol prep products is due to potential contamination of these products with the bacteria Bacillus cereus, which could lead to life-threatening infections.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
GJS
Device Class
Class II
Regulation
21 CFR Part 864.7750
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent

Other devices from Biosite Incorporated

See all devices from Biosite Incorporated →