← Back to catalogue

Inspire

FDA UDI

Class III (US FDA UDI)

by Inspire Medical Systems

Identity

Trade Name
Inspire FDA UDI
Generic Name
Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system FDA UDI
Device Name
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions. FDA UDI
Model / Reference
900-007-010 FDA UDI
Description
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions. FDA UDI

Identifiers

Catalog Number
3028 FDA UDI
Primary DI / UDI-DI
10855728005762 FDA UDI
PMA Number
P130008 FDA UDI
FDA Product Code
MNQ FDA UDI
GMDN Term
Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system FDA UDI

Classification

Device Class
Class III FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

Yes

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

Yes

FDA UDI
MRI Safety
MR Conditional FDA UDI

Category: Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system

Inspire by Inspire Medical Systems — Class III — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system.

Cleared under the same submission

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 28ad0a35-ac2d-4062-a9ac-b9e2c4c2ee55 35 fields · synced Jun 8, 2026