Inspire 8F Oxygenator with Integrated Arterial Filter & Hardshell Reservoir
by Sorin Group Italia S.R.L. 510(k)
Active
510(k) K121536
Overview
This device is a Cardiopulmonary Bypass Oxygenator (DTZ classification), designed for use during open-heart surgical procedures. It functions as a microporous hollow fiber membrane oxygenator, facilitating gas exchange by removing carbon dioxide and adding oxygen to venous blood. The integrated arterial filter reduces embolic risk, while the hardshell reservoir manages venous return and cardiotomy suction blood, ensuring efficient processing and temperature control.
The Inspire 8F Oxygenator is supplied as a single-use, sterile device intended for use in controlled surgical environments. It is classified as a Class II medical device under FDA regulations (K121536, 510(k) clearance) and adheres to cardiovascular-specific standards. The hardshell reservoir design and integrated arterial filter enhance performance in cardiopulmonary bypass circuits. Storage and handling must comply with sterile medical device protocols to maintain integrity prior to use.
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK121536 | Date22 Aug 2012 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not known
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DTZ
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.4350
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Other devices from Sorin Group Italia S.R.L.
Questions
What is the Inspire 8F Oxygenator designed for?
The Inspire 8F Oxygenator is specifically designed for use during open-heart surgical procedures, functioning as a cardiopulmonary bypass oxygenator. It facilitates gas exchange by removing carbon dioxide and adding oxygen to venous blood, ensuring efficient oxygenation while the heart is temporarily stopped or bypassed. The integrated arterial filter further reduces the risk of emboli, and the hardshell reservoir manages venous return and cardiotomy suction blood, maintaining optimal processing and temperature control throughout the procedure.
How is the Inspire 8F Oxygenator supplied and what are its sterility and reuse specifications?
The Inspire 8F Oxygenator is supplied as a single-use, sterile device. This design ensures patient safety by eliminating the risk of cross-contamination between uses. Single-use devices are intended for one-time use in controlled surgical environments, adhering to strict sterility protocols to maintain integrity before and during use. Reuse is not recommended or approved for this device.
What distinguishes the hardshell reservoir design in this oxygenator?
The hardshell reservoir in the Inspire 8F Oxygenator is engineered to manage venous return and cardiotomy suction blood efficiently. This design enhances performance by providing better temperature control and stability within the cardiopulmonary bypass circuit, reducing the risk of air entrainment and ensuring smoother blood processing during surgery. The rigid structure also supports consistent oxygenation and filtration, contributing to overall surgical safety.
How should the Inspire 8F Oxygenator be stored and handled?
The Inspire 8F Oxygenator must be stored and handled according to sterile medical device protocols to preserve its integrity. It should be kept in its original, unopened packaging until immediately before use, in a clean, dry environment protected from contamination, moisture, and extreme temperatures. Proper storage ensures the device remains sterile and functional, ready for use in controlled surgical settings as intended.
What regulatory classification does this device hold, and what standards does it adhere to?
The Inspire 8F Oxygenator is classified as a Class II medical device under FDA regulations and has received 510(k) clearance (K121536). It adheres to cardiovascular-specific standards, ensuring compliance with rigorous safety and performance requirements for use in cardiopulmonary bypass procedures. The device’s design and functionality have been evaluated to meet these regulatory criteria, guaranteeing reliability in clinical settings.