Insuflow Port 5mm
Ref 4100-5
Insuflow Port 5mm (4100-5) is a laparoscopic access cannula (EU MDD Class IIa; FDA Class II) made by Lexion Medical LLC, registered in EUDAMED on 12 Aug 2025 (Basic UDI-DI B-00852588007151), cleared under FDA 510(k) K170799 on 14 Nov 2017 and listed in FDA GUDID since 5 Nov 2020 (UDI-DI 00852588007151), active as of 22 Oct 2026.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00852588007151 00852588007151 | Date12 Aug 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00852588007151 | Date5 Nov 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK170799 | Date14 Nov 2017 | StatusActive |
Official records
- EUDAMED public site B-00852588007151
- AccessGUDID record 00852588007151
- FDA 510(k) database K170799
From the FDA record
- Device description
- 5mm x 100mm Insuflow Port
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- EUDAMED Basic UDI-DI B-00852588007151 registered 12 Aug 2025 Active
- FDA 510(k) K170799 decided 14 Nov 2017 Active
- FDA GUDID UDI-DI 00852588007151 listed 5 Nov 2020 Listed
Timeline
- Cleared FDA 510(k) K170799
- Listed FDA GUDID 00852588007151
- Registered EUDAMED B-00852588007151
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Insuflow Port 5mm EUDAMEDInsuflow Port GUDID
- Generic name
- Laparoscopic access cannula, single-use
- Model / Ref / Catalog
- 4100-5
- Primary DI / UDI-DI
- 00852588007151
- Basic UDI-DI
- B-00852588007151
- 510(k) Number
- FDA product code
- HIF, GCJ, OSV
- EMDN code
- K01010101 Trocar standard, single-use
- GMDN term
- Laparoscopic access cannula, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 884.1730, 876.1500
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 00852588007151: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Manufacturer details
- EUDAMED SRN
- US-MF-000033626
- Authorised representative
- Donawa Lifescience Consulting Srl IT-AR-000007785