← Back to catalogue

Integra Mishler Dual Chamber Flushing Valve

FDA UDI

Class II (US FDA UDI)

by Integra Lifesciences Corp.

Identity

Trade Name
Integra Mishler Dual Chamber Flushing Valve FDA UDI
Generic Name
Cerebrospinal fluid shunt valve FDA UDI
Device Name
VALVE FLUSH F/B D/C W/CONNECTOR The Integra Mishler Dual Chamber Flushing valve, Flat Bottom Design incorporates two separate interior chambers to provide two-way flow control when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. This silicone elastomer flushing valve is available with or without an integral Anti-Siphon Device. The flat bottom configuration eliminates the need for a formal burr hole, provides greater latitude in positioning the flushing valve and allows the ventricular catheter to be revised without disturbing the flushing valve. Due to the dual chamber feature, the proximal and distal catheters may be flushed separately or simultaneously. The flow of CSF from the ventricular catheter is controlled by a miter valve located on the vertical chamber divider. This valve is designed to open under a medium positive ventricular pressure and close under a negative pressure. The flushing valve dome is marked with an arrow to indicate the CSF flow direction. The flange overlying the skull contains sutural holes to facilitate securing the device to the periosteum. FDA UDI
Model / Reference
NL8500312 FDA UDI
Description
VALVE FLUSH F/B D/C W/CONNECTOR The Integra Mishler Dual Chamber Flushing valve, Flat Bottom Design incorporates two separate interior chambers to provide two-way flow control when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. This silicone elastomer flushing valve is available with or without an integral Anti-Siphon Device. The flat bottom configuration eliminates the need for a formal burr hole, provides greater latitude in positioning the flushing valve and allows the ventricular catheter to be revised without disturbing the flushing valve. Due to the dual chamber feature, the proximal and distal catheters may be flushed separately or simultaneously. The flow of CSF from the ventricular catheter is controlled by a miter valve located on the vertical chamber divider. This valve is designed to open under a medium positive ventricular pressure and close under a negative pressure. The flushing valve dome is marked with an arrow to indicate the CSF flow direction. The flange overlying the skull contains sutural holes to facilitate securing the device to the periosteum. FDA UDI

Identifiers

Catalog Number
NL8500312 FDA UDI
Primary DI / UDI-DI
10381780072256 FDA UDI
510(k) Number
K153041 FDA UDI
K760784 FDA UDI
FDA Product Code
JXG FDA UDI
GMDN Term
Cerebrospinal fluid shunt valve FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
882.5550 FDA UDI
Commercial Distribution
Not in Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

Yes

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI
MRI Safety
MR Conditional FDA UDI

Integra Mishler Dual Chamber Flushing Valve by Integra Lifesciences Corp. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Cleared under the same submission

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 15f5e043-8ff5-47da-af97-5007aa7e8578 38 fields · synced May 30, 2026