# Intelli-C Accessory 02919900

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/intelli-c-accessory-02919900>
- Manufacturer: [Nrt - Nordisk Røntgen Teknik A/S](https://devicerts.com/manufacturers/nrt-nordisk-rontgen-teknik-a-s) (Denmark)
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: OWB, JAA
- EMDN: Z11039080 VARIOUS RADIODIAGNOSTIC AND INTERVENTIONAL INSTRUMENTS - HARDWARE ACCESSORIES
- GMDN: Medical table top floor stand, non-powered (62758)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 571346413200AG · UDI-DI 05713464000329 · registered 2026-05-21 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 05713464000329 · listed 2019-01-21 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K173631 · decision 2018-07-11 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1784-2024 · Class II · ongoing · initiated 2024-04-17: X-ray system C-arm may experience uncontrolled motion if 1) AC motor controller firmware has a faulty setting, 2) the Motor/gear assembly is worn, 3) CAT movement is driven at maximum speed and angulated more than 75 deg. from vertical, and 4) the emergency stop or touch guard is activated during the breaking sequence, which could lead to the C-arm hitting the patient or operator.
- Z-1669-2023 · Class II · ongoing · initiated 2023-04-27: There is a potential that the drive shaft in the detector up/down (IDE) movement of the X-Ray machine may break which causes the detector to move until it is stopped by the movement end-stop.
- Z-1668-2023 · Class II · ongoing · initiated 2023-04-27: There is a potential that the drive shaft in the detector up/down (IDE) movement of the X-Ray machine may break which causes the detector to move until it is stopped by the movement end-stop.
- Z-0526-2022 · Class II · ongoing · initiated 2022-01-21: Friction rubber block in the clamping mechanism was missing in the Footrest. It may slip down along the patient table while in use with a patient. This accessory is designed to use with Intelli-C, Right and Intelli-C, Left.

## Identity

- Trade name: Table Top Support, CPR [EUDAMED]; Intelli-C Accessory [FDA GUDID (AccessGUDID)]
- Generic name: Medical table top floor stand, non-powered [FDA GUDID (AccessGUDID)]
- Model / reference: 02919900 [EUDAMED, FDA GUDID (AccessGUDID)]; CFP Accessories [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 05713464000329 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 571346413200AG [EUDAMED]
- Direct marketing DI: 05713464000329 [EUDAMED]
- 510(k) Number: K173631 [FDA GUDID (AccessGUDID)]
- FDA product code: OWB [FDA GUDID (AccessGUDID)]; JAA [FDA GUDID (AccessGUDID)]
- EMDN code: Z11039080 [EUDAMED]
- GMDN term: Medical table top floor stand, non-powered (62758) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1650 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Denmark [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Intelli-C Accessory 02919900, Nrt - Nordisk Røntgen Teknik A/S. deviCERTS medical device catalogue. https://devicerts.com/devices/intelli-c-accessory-02919900 (data as of 2026-11-16).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-16
- JSON: <https://devicerts.com/devices/intelli-c-accessory-02919900.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/intelli-c-accessory-02919900
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
