IntelliVue Patient Monitor MX750
by Philips Medizin Systeme Böblingen GmbH
Ref 866471
Active
Valid until
Not listed
FDA recalls
2 ongoingTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k) 510(k) | NumberK251702 | Date10 Nov 2025 | StatusActive |
| European Union | CE/MDR EUDAMED | Number0884838BM591TG 00884838083332 | Date15 May 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00884838083332 | Date29 Nov 2021 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-0870-2026
- Ongoing Z-0868-2026
Potential issue where the IntelliVue monitors did not alarm.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- United States
- European Union
Specification
- Generic Name
- Multiple vital physiological parameter monitoring system, clinical
- Model / Ref / Catalog
- 866471, IntelliVue Patient Monitor MX750
- Primary DI / UDI-DI
- 00884838083332
- Basic UDI-DI
- 0884838BM591TG
- Direct Marketing DI
- 00884838083332
- FDA Product Code
- MHX
- EMDN Code
- Z1203020201 Multi–parameter patient bedside monitors
- GMDN Term
- Multiple vital physiological parameter monitoring system, clinical
- Device Class
- Class IIb EUDAMEDClass II GUDID
- Regulation Number
- 870.1025
- EU market of registration
- Austria
- GUDID distribution status
- In Commercial Distribution
- MRI Safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | 866471 | IntelliVue Patient Monitor MX750 |
| Device Class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- DE-MF-000006026
Overview
AI-generated summary, 18 Sep 2026
The IntelliVue Patient Monitor MX750/850 is a Class IIb medical device classified under nomenclature code Z1203020201, designed for continuous patient monitoring in clinical settings. It provides real-time measurement and display of vital signs, including physiological parameters such as ECG, blood pressure, pulse oximetry, and respiratory rate, enabling clinicians to assess patient status and respond to changes promptly.
This device is intended for single-use applications in hospital environments, though it is not sterile or implantable. Supplied as a non-reusable unit, it operates within standard regulatory frameworks, including FDA 510(k) and MDR compliance. The monitor is equipped with a unique Device Identifier (DI) and UDI data for traceability, ensuring adherence to global medical device standards. Storage and handling follow manufacturer guidelines to maintain functionality and safety.
Other devices from Philips Medizin Systeme Böblingen GmbH
See all devices from Philips Medizin Systeme Böblingen GmbH →
Properties
Other properties (21)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
- Manufacturing Date: No