Interference Screw 909660
Ref 909660
Interference Screw 909660 is a device classified as Class IIb in the EU and Class II in the US made by Biomet Orthopedics, Inc., registered in EUDAMED on 26 Oct 2026 (Basic UDI-DI B-00880304008311), cleared under FDA 510(k) K193451 on 24 Feb 2020 (1 earlier submission) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304008311), active as of 7 Nov 2026. 2 FDA recalls are linked to it.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00880304008311 00880304008311 | Date26 Oct 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK193451 | Date24 Feb 2020 | StatusActive |
| United States | GUDID listing GUDID | Number00880304008311 | Date24 Oct 2015 | StatusListed |
Official records
- EUDAMED public site B-00880304008311
- AccessGUDID record 00880304008311
- FDA 510(k) database K193451
- FDA 510(k) database K934469
Across registries
- EUDAMED Basic UDI-DI B-00880304008311 registered 26 Oct 2026 Active
- FDA 510(k) K193451 decided 24 Feb 2020 Active
- FDA GUDID UDI-DI 00880304008311 listed 24 Oct 2015 Listed
Recalls
-
- Terminated Z-0630-2021
Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.
-
- Terminated Z-0753-2013
Thru hole at the tip of the screw is undersized.
Timeline
- Cleared FDA 510(k) K934469
- Recall initiated FDA recalls Z-0753-2013
- Listed FDA GUDID 00880304008311
- Cleared FDA 510(k) K193451
- Recall initiated FDA recalls Z-0630-2021
- Registered EUDAMED B-00880304008311
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Interference Screw
- Generic name
- Tendon/ligament bone anchor, non-bioabsorbable
- Device name
- Round Head TI Interference Screw Implant
- Model / Ref / Catalog
- 909660
- Primary DI / UDI-DI
- 00880304008311
- Basic UDI-DI
- B-00880304008311
- FDA product code
- HWC, MBI
- EMDN code
- P09120605 Interference screws
- GMDN term
- Tendon/ligament bone anchor, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3040
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under INTERFERENCE SCREWS.
- PROPEL C8944 by Conmed Corporation
- INTERFIX PEEK INTERFERENCE SCREW 6 X 25 MM TM04120625 by Tulpar Tıbbi Ürünler İthalat İhracat Sanayi ve Ticaret L.T.D Ş.T.İ
- ActivaScrew™ Interference B-AI-0824 by Bioretec Ltd.
- PROPEL C8610 by Conmed Corporation
- MectaScrew C 05.05.0110 by Medacta International
- 10001 by Innovate Orthopaedics, Ltd.
- Osteon SCRW-OBCS4570 by Bonegraft Biomaterials Co.
- ComposiTCP 60 flat head 905261 by S.B.M
- PEEK CF Interference Screw 10036 by PARCUS MEDICAL LLC
- Powerbone C-SCRW-PBS1534 by Bonegraft Biomaterials Co.