Skip to content

Interlocking Femoral Nailing System

by Stryker Corp.

510(k) K912930

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK912930 Date13 Jan 1992ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
HSB
Device class
Class II
Regulation
21 CFR Part 888.3020
Advisory committee
Orthopedic
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Interlocking Femoral Nailing System is an orthopedic implant classified as an intramedullary nail (Device Type: HSB). It is designed for the internal fixation of femoral shaft fractures, providing mechanical stability through interlocking screws to secure the nail in place. This system supports both antegrade and retrograde insertion techniques, accommodating a range of fracture patterns in the femur. Its construction allows for load-sharing and alignment correction during the healing process.

This device is supplied sterile and intended for single-use. It is regulated under FDA 510(k) clearance (K912930) and falls under the Orthopedic Advisory Committee classification. The system includes modular components such as nails and interlocking screws, available in standardized sizes to match femoral anatomy. Storage requires adherence to sterile packaging protocols, and its design ensures compatibility with standard orthopedic surgical procedures. No MRI safety information is specified.

Other devices from Stryker Corp.

See all devices from Stryker Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Interlocking Femoral Nailing System used for?

    This system is designed for internal fixation of femoral shaft fractures. It provides mechanical stability by securing an intramedullary nail in place with interlocking screws, enabling load-sharing and alignment correction during bone healing. The modular design accommodates various fracture patterns and supports both antegrade (from hip to knee) and retrograde (from knee to hip) insertion techniques.

  • How is the Interlocking Femoral Nailing System supplied and intended for use?

    The system is supplied sterile and is intended for single-use only. Each component, including nails and interlocking screws, is packaged separately to maintain sterility until use. This ensures compliance with surgical standards and minimizes infection risk during orthopedic procedures.

  • What sizes and models are available for the Interlocking Femoral Nailing System?

    The system includes standardized modular components tailored to match femoral anatomy. Nails and interlocking screws are available in multiple sizes to fit different patient anatomies and fracture types. The modular design allows for flexibility in surgical planning, ensuring proper fit and stability for each case.

  • How should the Interlocking Femoral Nailing System be stored?

    Storage must adhere to sterile packaging protocols to preserve the device’s sterility. Components should remain in their original, unopened packaging until immediately before use. Proper storage conditions prevent contamination and ensure the system remains ready for sterile surgical environments.

  • Is MRI safety information provided for this device?