# Interventional Angiography System Infx-8000C

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/interventional-angiography-system-infx-8000c>
- Manufacturer: [Canon Inc.](https://devicerts.com/manufacturers/canon-inc) (Japan)
- Name in the registry: INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C
- Device class: Class IIb (EU MDR); Class II (US FDA)
- FDA product code: JAA, OWB, MQB
- EMDN: Z11030102 STATIONARY ANGIOGRAPHY SYSTEMS FOR ANGIOGRAPHIC AND CARDIOLOGIC STUDIES
- GMDN: Stationary angiographic x-ray system, digital (37623)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 4987670A0101QY · UDI-DI 04987670100192 · registered 2026-06-15 · status: Active
- **GUDID** · FDA 510(k) · United States · K181804 · decision 2018-08-02 · decision SESE · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 04987670100192 · listed 2016-09-01 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K152697 · decision 2016-01-15 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K113052 · decision 2011-11-22 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1289-2022 · Class II · ongoing · initiated 2022-05-03: CT operation may be restricted by an interlock which is a result of an system error and the CT system may stop operating properly after an attempt to cancel the error message has been initiated.
- Z-0492-2022 · Class II · ongoing · initiated 2021-12-20: Abnormal images such as horizontal stripes may be displayed and recovery may not not be possible by restarting the system. The worst case scenario is an operator who is working without a workable image may remove a catheter from the patient's blood vessel and damage the blood vessel.
- Z-1175-2021 · Class II · ongoing · initiated 2021-02-05: The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
- Z-1270-2021 · Class II · ongoing · initiated 2020-12-08: System table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose.
- Z-0532-2021 · Class II · terminated · initiated 2020-10-08: There is a potential that the cable of the Flat panel detector may break during a procedure which may cause the x-ray device to stop before the examination is completed. This could result in a delay with procedure and/or potential damage to the patients blood vessels due to removal without visibility.
- Z-2326-2020 · Class II · ongoing · initiated 2020-03-03: Bolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting.
- Z-0843-2018 · Class II · terminated · initiated 2017-12-29: During an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error.
- Z-0994-2013 · Class II · terminated · initiated 2012-11-08 · matched through shared submission K113052, may concern other models: Lost and incorrect images. When using the "F-Rec" fluoroscopy image acquisition recording option in the "manual mode" an infrequent software error may cause images from another study to be displayed on the monitor. The acquired images may be lost requiring additional image acquisitions to be performed.

## Identity

- Trade name: INTERVENTIONAL ANGIOGRAPHY SYSTEM [FDA GUDID (AccessGUDID)]
- Generic name: Stationary angiographic x-ray system, digital [FDA GUDID (AccessGUDID)]
- Model / reference: INFX-8000C [EUDAMED, FDA GUDID (AccessGUDID)]; INFX-8000F [EUDAMED]; etc. [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 04987670100192 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 4987670A0101QY [EUDAMED]
- 510(k) Number: K113052 [FDA GUDID (AccessGUDID)]; K152697 [FDA GUDID (AccessGUDID)]; K181804 [FDA GUDID (AccessGUDID)]
- FDA product code: JAA [FDA GUDID (AccessGUDID)]; OWB [FDA GUDID (AccessGUDID)]
- EMDN code: Z11030102 [EUDAMED]
- GMDN term: Stationary angiographic x-ray system, digital (37623) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1650 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: France [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Interventional Angiography System Infx-8000C, Canon Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/interventional-angiography-system-infx-8000c (data as of 2026-11-22).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-22
- JSON: <https://devicerts.com/devices/interventional-angiography-system-infx-8000c.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/interventional-angiography-system-infx-8000c
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.