Skip to content

Intra-Aortic Balloon (IAB)

by Arrow Intl., Inc.

510(k) K040801

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

13 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK040801 Date6 May 2004ClearedStatusActive

Recalls

13 recalls · FDA

  • 13 recalls, same reason

    • Terminated Z-1212-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1218-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1216-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1210-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1220-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1214-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1213-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1211-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1217-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1219-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1215-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1221-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009
    • Terminated Z-1222-2009 FDA Unclassified (pre-2012) initiated 2 Feb 2009

    A fault in the connector of the pump tubing assembly may result in the volume setting on the pump defaulting to 2.5 ccs or 5 ccs (depending on IABP model) rather than the appropriate 30, 40, or 50 cc volume.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DSP
Device Class
Class II
Regulation
21 CFR Part 870.3535
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Intra-Aortic Balloon (IAB) is a mechanical circulatory support device classified as a System, Balloon, Intra-Aortic And Control. It is designed to augment cardiac output by inflating and deflating a balloon positioned within the descending aorta in synchrony with the cardiac cycle, thereby improving coronary and systemic perfusion during diastole and reducing afterload during systole.

This device is intended for use in cardiac and non-cardiac surgical procedures, acute coronary syndrome, and complications of heart failure. Supplied as a reusable system with a control unit, the IAB is regulated under FDA 510(k) clearance (K040801) and falls under device classification II (DSP). It is not described as single-use or sterile in the provided data, and MRI safety or specific size details are not specified.

Other devices from Arrow Intl., Inc.

See all devices from Arrow Intl., Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical scenarios is this Intra-Aortic Balloon (IAB) system intended for use in, and how does it work?

    The Intra-Aortic Balloon (IAB) system is designed for use during cardiac and non-cardiac surgical procedures, acute coronary syndrome, and complications of heart failure. It works by positioning a balloon in the descending aorta, which inflates and deflates in sync with the heart’s cycle. This improves blood flow to the heart and body during diastole (when the heart relaxes) and reduces the workload on the heart during systole (when the heart contracts), thereby enhancing cardiac output and perfusion.

  • Is this device single-use or reusable, and what does that mean for maintenance and cost?

    The Intra-Aortic Balloon system is supplied as a reusable device, meaning it is intended for repeated use after proper cleaning, disinfection, and maintenance. This design can impact cost over time, as it requires ongoing upkeep rather than replacement after each use, but it may also reduce waste and long-term expenses for facilities with high usage.

  • What regulatory pathway was followed for this device’s approval, and which committee was involved?

    This Intra-Aortic Balloon system received FDA clearance through the 510(k) pathway, specifically under the classification of Special and the product code DSP. The device was reviewed by the Cardiovascular (CV) Advisory Committee, which evaluates medical devices related to heart function and circulatory support.

  • Are there different sizes or models available for this device, and how might that affect patient selection?

    The provided data does not specify exact sizes or models, but the device is listed with multiple registration numbers, suggesting variations may exist to accommodate different patient anatomies or clinical needs. Facilities should consult the manufacturer’s documentation to determine compatibility with specific patient profiles, as sizing would influence proper placement and effectiveness.

  • How should this reusable device be stored to ensure proper functionality and longevity?

    Since the Intra-Aortic Balloon system is reusable, storage instructions would typically include keeping it in a clean, dry environment away from direct sunlight or extreme temperatures. The manufacturer’s guidelines likely outline specific cleaning, disinfection, and maintenance protocols to prevent damage, ensure sterility between uses, and maintain performance over time. Always refer to the provided instructions for storage and handling.