Skip to content

InTrack Clamp N-10003v

by Vitalitec International, Inc.

Part of a family of 35 devices: see the family page

Ref N-10003V

InTrack Clamp N-10003v is a clamp manipulation forceps (EU MDR Class I; FDA Class II; FDA product code DXC, Clamp, Vascular) made by Vitalitec International, Inc., registered in EUDAMED on 27 Oct 2026 (Basic UDI-DI 0852621004ClampsKJ), cleared under FDA 510(k) K992640 on 8 Sep 1999 and listed in FDA GUDID since 13 Dec 2018 (UDI-DI 00852621004338), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 7 Nov 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K992640

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0852621004ClampsKJ Basic UDI-DI 00852621004338UDI-DIDate27 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00852621004338 UDI-DI Date13 Dec 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK992640 Date8 Sep 1999DecidedStatusActive

Official records

From the FDA record

Device description
Reusable, Surgical Vascular Clamp for vessel occlusion
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0852621004ClampsKJ registered 27 Oct 2026 Active
  • FDA 510(k) K992640 decided 8 Sep 1999 Active
  • FDA GUDID UDI-DI 00852621004338 listed 13 Dec 2018 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K992640
  2. Listed FDA GUDID 00852621004338
  3. Registered EUDAMED 0852621004ClampsKJ

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Intrack® Surgical Clamp EUDAMED
InTrack Clamp GUDID
Generic name
Clamp manipulation forceps
Device name
Intrack Surgical Clamp
Model / reference
N-10003v
Primary DI / UDI-DI
00852621004338
Basic UDI-DI
0852621004ClampsKJ
510(k) Number
FDA product code
DXC
EMDN code
L070899 Vascular surgery instruments, reusable - other
GMDN term
Clamp manipulation forceps
Device class
Class I EUDAMED
Class II GUDID
Regulation number
870.4450
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Length — 66 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CARDIOVASCULAR SURGERY INSTRUMENTS, REUSABLE.

Other devices from Vitalitec International, Inc.

See all devices from Vitalitec International, Inc. →

Properties

  • Sterilise before use
  • Reusable
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)