# Iolmaster 500

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/iolmaster-500-hjo>
- Manufacturer: [Carl Zeiss Meditec AG](https://devicerts.com/manufacturers/carl-zeiss-meditec-ag) (Germany)
- Name in the registry: IOLMASTER 500
- Device class: Class II (US FDA)
- FDA product code: HJO

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K101182 · decision 2010-11-03 · decision SESE · status: Active

## Recalls

- Z-0357-2016 · Class II · terminated · initiated 2015-10-27: IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.
- Z-0358-2016 · Class II · terminated · initiated 2015-10-27: IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.
- Z-0333-2014 · Class II · terminated · initiated 2013-10-23: The user database delivered for download contained an erroneous value. Specifically the "aO" constant of the lens AMO Sensar AR40E is listed as "0.0" in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.
- Z-0334-2014 · Class II · terminated · initiated 2013-10-23: The user database delivered for download contained an erroneous value. Specifically the "aO" constant of the lens AMO Sensar AR40E is listed as "0.0" in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.

## Identifiers

- 510(k) Number: K101182 [FDA 510(k)]
- FDA product code: HJO [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 886.1850 [FDA 510(k)]
- Advisory committee: Ophthalmic [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Iolmaster 500, Carl Zeiss Meditec AG. deviCERTS medical device catalogue. https://devicerts.com/devices/iolmaster-500-hjo (data as of 2026-11-25).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/iolmaster-500-hjo.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/iolmaster-500-hjo
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.