Skip to content

IOLMaster 500

by Carl Zeiss Meditec AG

Ref 1692-983Model IOLMaster 500

IOLMaster 500 is a medical device (EU MDD Class IIa; FDA Class II; FDA product code HJO, Biomicroscope, Slit-Lamp, Ac-Powered; EMDN category computerised optical biometers) made by Carl Zeiss Meditec AG, registered in EUDAMED on 29 Jul 2026 (Basic UDI-DI B-04049471092066), cleared under FDA 510(k) K141068 on 9 Sep 2014 (1 earlier submission) and listed in FDA GUDID since 18 Mar 2016 (UDI-DI 04049471092066), active as of 17 Oct 2026. 4 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

4 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 17 Oct 2026.

Regulatory status

as of registry sync 17 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-04049471092066 Basic UDI-DI 04049471092066UDI-DIDate29 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04049471092066 UDI-DI Date18 Mar 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK141068 Date9 Sep 2014DecidedStatusActive

Official records

From the FDA record

Device description
The IOLMaster is intended for the biometric determination of ocular measurements for axial length, anterior chamber depth, corneal radius, white-to-white (WTW), and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. For patients who are candidates for intraocular lens (IOL) implantation, the device also performs calculations to assist physicians in determining the appropriate IOL power and type for implantation.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 17 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-04049471092066 registered 29 Jul 2026 Active
  • FDA 510(k) K141068 decided 9 Sep 2014 Active· +1 more in the status table
  • FDA GUDID UDI-DI 04049471092066 listed 18 Mar 2016 Listed

Recalls

4 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-0358-2016 FDA Class II initiated 27 Oct 2015
    • Terminated Z-0357-2016 FDA Class II initiated 27 Oct 2015

    IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.

  • 2 recalls, same reason

    • Terminated Z-0333-2014 FDA Class II initiated 23 Oct 2013
    • Terminated Z-0334-2014 FDA Class II initiated 23 Oct 2013

    The user database delivered for download contained an erroneous value. Specifically the "aO" constant of the lens AMO Sensar AR40E is listed as "0.0" in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.

Timeline

8 dated events

  1. Cleared FDA 510(k) K122418
  2. Recall initiated FDA recalls Z-0333-2014
  3. Recall initiated FDA recalls Z-0334-2014
  4. Cleared FDA 510(k) K141068
  5. Recall initiated FDA recalls Z-0358-2016
  6. Recall initiated FDA recalls Z-0357-2016
  7. Listed FDA GUDID 04049471092066
  8. Registered EUDAMED B-04049471092066

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
IOLMaster EUDAMED
IOLMaster 500 GUDID
Generic name
Optical low coherence reflectometry (OLCR) biometer
Model / reference
IOLMaster 500, 1692-983
Primary DI / UDI-DI
04049471092066
Basic UDI-DI
B-04049471092066
Direct marketing DI
04049471092066
510(k) Number
FDA product code
HJO
EMDN code
Z12120102 Computerised optical biometers
GMDN term
Optical low coherence reflectometry (OLCR) biometer
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
886.1850
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Size
Weight — 18 Kilogram

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under COMPUTERISED OPTICAL BIOMETERS.

Other devices from Carl Zeiss Meditec AG

See all devices from Carl Zeiss Meditec AG →

Properties

  • Measuring function
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)