# IOLMaster 500

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/iolmaster-500-iolmaster-500>
- Manufacturer: [Carl Zeiss Meditec AG](https://devicerts.com/manufacturers/carl-zeiss-meditec-ag) (Germany)
- Device class: Class IIa (EU MDD); Class II (US FDA)
- FDA product code: HJO
- EMDN: Z12120102 COMPUTERISED OPTICAL BIOMETERS
- GMDN: Optical low coherence reflectometry (OLCR) biometer (48064)

## Registrations and authorizations

- **EUDAMED** · CE/MDD · European Union · Basic UDI-DI B-04049471092066 · UDI-DI 04049471092066 · registered 2026-07-29 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 04049471092066 · listed 2016-03-18 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K141068 · decision 2014-09-09 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K122418 · decision 2013-04-12 · decision SESE · status: Active · from GUDID

## Recalls

- Z-0358-2016 · Class II · terminated · initiated 2015-10-27: IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.
- Z-0357-2016 · Class II · terminated · initiated 2015-10-27: IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.
- Z-0333-2014 · Class II · terminated · initiated 2013-10-23: The user database delivered for download contained an erroneous value. Specifically the "aO" constant of the lens AMO Sensar AR40E is listed as "0.0" in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.
- Z-0334-2014 · Class II · terminated · initiated 2013-10-23: The user database delivered for download contained an erroneous value. Specifically the "aO" constant of the lens AMO Sensar AR40E is listed as "0.0" in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.

## Identity

- Trade name: IOLMaster [EUDAMED]; IOLMaster 500 [FDA GUDID (AccessGUDID)]
- Generic name: Optical low coherence reflectometry (OLCR) biometer [FDA GUDID (AccessGUDID)]
- Model / reference: IOLMaster 500 [EUDAMED, FDA GUDID (AccessGUDID)]; 1692-983 [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 04049471092066 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-04049471092066 [EUDAMED]
- Direct marketing DI: 04049471092066 [EUDAMED]
- 510(k) Number: K122418 [FDA GUDID (AccessGUDID)]; K141068 [FDA GUDID (AccessGUDID)]
- FDA product code: HJO [FDA GUDID (AccessGUDID)]
- EMDN code: Z12120102 [EUDAMED]
- GMDN term: Optical low coherence reflectometry (OLCR) biometer (48064) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 886.1850 [FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]
- EU market of registration: Germany [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Weight — 18 Kilogram [FDA GUDID (AccessGUDID)]

## Properties

- Measuring function: Yes [EUDAMED]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: IOLMaster 500, Carl Zeiss Meditec AG. deviCERTS medical device catalogue. https://devicerts.com/devices/iolmaster-500-iolmaster-500 (data as of 2026-11-17).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-17
- Statuses computed as of: 2026-11-17
- JSON: <https://devicerts.com/devices/iolmaster-500-iolmaster-500.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/iolmaster-500-iolmaster-500
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.