# IOLMaster 700

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/iolmaster-700-hjo>
- Manufacturer: [Carl Zeiss Meditec AG](https://devicerts.com/manufacturers/carl-zeiss-meditec-ag) (Germany)
- Device class: Class II (US FDA)
- FDA product code: HJO

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The IOLMaster 700 is an optical biometry device designed for precise measurement of ocular parameters. It falls under the category of slit-lamp biomicroscopes and is used to assess key metrics such as axial length, corneal curvature, anterior chamber depth, and white-to-white corneal diameter. These measurements are critical for intraocular lens (IOL) calculations in cataract surgery planning, ensuring accurate lens power selection and optimal visual outcomes.

The IOLMaster 700 is a reusable, non-sterile device intended for use in clinical ophthalmic settings. It operates using optical coherence principles to capture high-resolution images of the eye without contact, minimizing patient discomfort. The device requires AC power and is classified as a Class II medical device under FDA regulations, with a 510(k) clearance for ophthalmic applications. Proper calibration and maintenance are essential for consistent performance, and it should be stored in a clean, controlled environment as per manufacturer guidelines.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K170171 · decision 2017-04-06 · decision SESE · status: Active

## Recalls

- Z-0108-2019 · Class II · terminated · initiated 2018-06-25: Calibration setting was incorrectly entered during manufacturing causing the optical coherence tomography (OCT) to obtain the incorrect two-dimensional images of ocular structures of the anterior and posterior segments of the eye.

## Identifiers

- 510(k) Number: K170171 [FDA 510(k)]
- FDA product code: HJO [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 886.1850 [FDA 510(k)]
- Advisory committee: Ophthalmic [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: IOLMaster 700, Carl Zeiss Meditec AG. deviCERTS medical device catalogue. https://devicerts.com/devices/iolmaster-700-hjo (data as of 2026-11-25).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/iolmaster-700-hjo.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/iolmaster-700-hjo
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
