{
  "format": "devicerts.device.v1",
  "cite_as": "iQ200 Elite Plus (US) (2008 Version) (NA), Beckman Coulter Ireland Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/iq200-700-3375 (data as of 2026-11-16).",
  "source": {
    "canonical_url": "https://devicerts.com/devices/iq200-700-3375",
    "json_url": "https://devicerts.com/devices/iq200-700-3375.json",
    "markdown_url": "https://devicerts.com/devices/iq200-700-3375.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "FDA GUDID (AccessGUDID)",
        "url": "https://accessgudid.nlm.nih.gov/"
      },
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      },
      {
        "registry": "FDA recalls",
        "url": "https://open.fda.gov/apis/device/recall/"
      }
    ],
    "registry_records_last_synced": "2026-10-24",
    "status_as_of": "2026-11-16",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/devices/iq200-700-3375",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "device": {
    "name": "iQ200 Elite Plus (US) (2008 Version) (NA)",
    "registry_name": "iQ200 Elite Plus (US) (2008 Version) (NA)",
    "url": "https://devicerts.com/devices/iq200-700-3375",
    "manufacturer": {
      "name": "Beckman Coulter Ireland Inc.",
      "url": "https://devicerts.com/manufacturers/beckman-coulter-ireland-inc",
      "country": "Ireland",
      "country_basis": null,
      "fda_registration_country": null
    },
    "status": {
      "state": "active",
      "label": "Active",
      "detail": "European Union and United States"
    },
    "classification": [
      {
        "class": "IVD General",
        "system": "EU IVDD"
      },
      {
        "class": "Class I",
        "system": "US FDA"
      }
    ],
    "identifiers": [
      {
        "label": "Catalogue number",
        "values": [
          {
            "value": "700-3375",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      },
      {
        "label": "Primary DI / UDI-DI",
        "values": [
          {
            "value": "10837461001355",
            "registries": [
              "EUDAMED",
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      },
      {
        "label": "Basic UDI-DI",
        "values": [
          {
            "value": "B-10837461001355",
            "registries": [
              "EUDAMED"
            ]
          }
        ]
      },
      {
        "label": "510(k) Number",
        "values": [
          {
            "value": "K022774",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      }
    ],
    "product_codes": [
      "KQO",
      "LKM"
    ],
    "emdn": [
      {
        "code": "W02010701",
        "term": "URINALYSIS (UR) - LABORATORY ANALYSERS- INSTRUMENTS"
      }
    ],
    "gmdn": [
      {
        "code": "35918",
        "term": "Urine analyser IVD, laboratory"
      }
    ],
    "description": null,
    "noindex": false
  },
  "authorizations": [
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/IVDD",
      "number": "B-10837461001355",
      "number_label": "Basic UDI-DI",
      "device_udi_di": "10837461001355",
      "date": "2026-08-13",
      "date_kind": "registered",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "GUDID listing",
      "number": "10837461001355",
      "number_label": "UDI-DI",
      "device_udi_di": null,
      "date": "2016-09-07",
      "date_kind": "listed",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Listed",
      "status_note": "GUDID: in commercial distribution",
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "FDA 510(k)",
      "number": "K022774",
      "number_label": null,
      "device_udi_di": null,
      "date": "2002-10-21",
      "date_kind": "decision",
      "decision_code": "SESE",
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": true
    }
  ],
  "no_longer_listed_by": [],
  "certificates": [],
  "recalls": [
    {
      "number": "Z-0160-2027",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2026-08-12",
      "reason": "The rinse-line check valve has a shorter service lifespan than originally expected and requires annual replacement\nto prevent lamina fluid leakage; however, the check valve replacement was excluded from the annual\npreventive maintenance (PM) requirements without adequate reliability evaluation. When the check\nvalve is not replaced annually, it may allow lamina fluid to migrate internally and leak onto the table or floor,\npotentially resulting in exposure to physical hazards (slip/fall), chemical hazards (lamina fluid exposure),\nbiohazardous exposure, property damage, and delayed patient results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0161-2027",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2026-08-12",
      "reason": "The rinse-line check valve has a shorter service lifespan than originally expected and requires annual replacement\nto prevent lamina fluid leakage; however, the check valve replacement was excluded from the annual\npreventive maintenance (PM) requirements without adequate reliability evaluation. When the check\nvalve is not replaced annually, it may allow lamina fluid to migrate internally and leak onto the table or floor,\npotentially resulting in exposure to physical hazards (slip/fall), chemical hazards (lamina fluid exposure),\nbiohazardous exposure, property damage, and delayed patient results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0786-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-12-19",
      "reason": "Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0784-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-12-19",
      "reason": "Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0785-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-12-19",
      "reason": "Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0787-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-12-19",
      "reason": "Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1597-2023",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-04-05",
      "reason": "Beckman Coulter has become aware of an intermittent issue in which the optional flag \"Previous Sample Had Sperm\" was enabled but not displayed so that a carryover event could have been investigated.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1598-2023",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-04-05",
      "reason": "Beckman Coulter has become aware of an intermittent issue in which the optional flag \"Previous Sample Had Sperm\" was enabled but not displayed so that a carryover event could have been investigated.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1596-2023",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-04-05",
      "reason": "Beckman Coulter has become aware of an intermittent issue in which the optional flag Previous Sample Had Sperm was enabled but not displayed so that a carryover event could have been investigated.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1599-2023",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2023-04-05",
      "reason": "Beckman Coulter has become aware of an intermittent issue in which the optional flag \"Previous Sample Had Sperm\" was enabled but not displayed so that a carryover event could have been investigated.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1945-2020",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2020-03-30",
      "reason": "A defect in the SATA power adapter cable within the instrument s computer has the potential risk for an electrical short that may lead to the following outcomes: charring and/or melting of the SATA adapter cable within the computer s metal enclosure, smoke emanating from PC6, flames contained within PC6, or an inability to use the device s CD-ROM.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-0914-2020",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2019-10-28",
      "reason": "Customers have reported incidents where two sets of results report the same Specimen Identifier (Specimen ID) with different results, different Medical Record Number (MRN) and different patient identification (demographics).",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1362-2018",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2018-03-02",
      "reason": "Beckman Coulter has determined that there is a potential for under-reporting casts. This can occur if per high-power field (/HPF) units of measurement for casts are selected in the iQ200 software, but the abnormal threshold and/or grading format is set up based on reporting  per low-power field (/LPF)* or *per microliter.  This may occur during initial method validation or if settings are altered after the initial validation.",
      "applies": "this device",
      "via": "K022774"
    },
    {
      "number": "Z-1366-2018",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2017-11-10",
      "reason": "iQ200 Series Urine Microscopy Analyzer may intermittently fail to read urine sample dilution barcode labels causing erroneous results that could delay treatment for health conditions such as hematuria.",
      "applies": "this device",
      "via": "K022774"
    }
  ],
  "eu_market_availability": null,
  "properties": [
    {
      "group": "Identity",
      "fields": [
        {
          "label": "Trade name",
          "values": [
            {
              "value": "iQ200",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Generic name",
          "values": [
            {
              "value": "Urine analyser IVD, laboratory",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Model / Ref / Catalog",
          "values": [
            {
              "value": "700-3370",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "700-3375",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            },
            {
              "value": "700-3375RFB",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "700-3376",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "B48999",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "C10683",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "Elite Plus (US) (2008 Version) (NA)",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Description",
          "values": [
            {
              "value": "\"iQ200 Elite 2008 Tested;\n800-3934 iQ®200 Elite Plus (US) (2008 Version) (NA);\n800-7714 IRICELL 2000 Plus (NA)\"",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Identifiers",
      "fields": [
        {
          "label": "Primary DI / UDI-DI",
          "values": [
            {
              "value": "10837461001355",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Basic UDI-DI",
          "values": [
            {
              "value": "B-10837461001355",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "510(k) Number",
          "values": [
            {
              "value": "K022774",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "FDA product code",
          "values": [
            {
              "value": "KQO",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            },
            {
              "value": "LKM",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EMDN code",
          "values": [
            {
              "value": "W02010701",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GMDN term",
          "values": [
            {
              "value": "Urine analyser IVD, laboratory",
              "code": "35918",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Classification",
      "fields": [
        {
          "label": "Device class",
          "values": [
            {
              "value": "Class IVD General",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "Class I",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Regulation number",
          "values": [
            {
              "value": "862.2900",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            },
            {
              "value": "864.5200",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EU registration type",
          "values": [
            {
              "value": "Legacy device (under a directive)",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "EU market of registration",
          "values": [
            {
              "value": "Ireland",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GUDID distribution status",
          "values": [
            {
              "value": "In Commercial Distribution",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Properties",
      "fields": [
        {
          "label": "Professional testing",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "IVD instrument",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Prescription use",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Serial number",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Supplied sterile",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Sterilise before use",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Single use",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Implantable",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Contains latex",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Contains human tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains animal tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains substances of microbial origin",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Reagent",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "IVD kit",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Self-testing",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Near-patient testing",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Companion diagnostics",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Over-the-counter",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Convenience kit",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Combination product",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "HCT/P",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Premarket exempt",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Lot / batch number",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Expiration date",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Manufacturing date",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    }
  ]
}
