Iradimed 3861
Iradimed 3861 is a bedside infusion pump (FDA Class II; FDA product code FRN, Pump, Infusion) made by Iradimed Corporation, cleared under FDA 510(k) K090087 on 7 Apr 2009 and listed in FDA GUDID since 25 Aug 2016 (UDI-DI 00856038001072), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00856038001072 | Date25 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK090087 | Date7 Apr 2009 | StatusActive |
Official records
- AccessGUDID record 00856038001072
- FDA 510(k) database K090087
From the FDA record
- Device description
- MRIDIUM 3861 SIDECAR SECOND CHANNEL (INFUSION PUMP)
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K090087 decided 7 Apr 2009 Active
- FDA GUDID UDI-DI 00856038001072 listed 25 Aug 2016 Listed
Recalls
-
- Ongoing Z-1310-2023
Certain Iradimed 1057 Syringe Adapter Sets, used with the MRidium MRI infusion pump, have a problem relating to a defective injection molded part which can limit the effectiveness of the syringe venting function which then can result in occlusion.
-
- Terminated Z-1874-2013
The Dose Error Reduction System (DERS) can indicate an incorrect recommended value for the rate via a specific key sequence during the initial infusion setup. This can result in a risk of over-infusion or under-infusion if the infusion is started with this rate value.
Timeline
- Cleared FDA 510(k) K090087
- Recall initiated FDA recalls Z-1874-2013
- Listed FDA GUDID 00856038001072
- Recall initiated FDA recalls Z-1310-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Iradimed
- Generic name
- Bedside infusion pump, multichannel
- Model / Ref / Catalog
- 3861
- Primary DI / UDI-DI
- 00856038001072
- 510(k) Number
- FDA product code
- FRN
- GMDN term
- Bedside infusion pump, multichannel
- Device class
- Class II
- Regulation number
- 880.5725
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Similar devices
Other devices filed under FDA product code FRN (Pump, Infusion).
- VOLUMETRIC INFUSION PUMP by American Edwards Laboratories
- BARD MICROINFUSER I INSULIN INFUSION PUMP by C. R. Bard, Inc.
- WALKMED 300, WALKMED 350, WALKMED IC, WALKMED PCA, WALKMED PLUS by Mckinley, Inc.
- SIDEKICK INFUSION KIT by I-Flow Corp.
- RMS Precision Flow Rate TubingTM F2400 by REPRO MED SYSTEMS, INC.
- MICROJET CRONO by Cane S.R.L.
- AUTO SYRINGE AS40A INFUSION PUMP by Baxter Corp.
- AVI GUARDIAN 400 INFUSION PUMP by Avi, Inc.
- MINI-PUMP U-100 by Advanced Bio Systems, Inc.
- BAXTER BEDSIDE SYSTEM by Travenol Laboratories, S.A.