ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry Analyzer
510(k) K161837
Active
Valid until
Not listed
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE 510(k) | NumberK161837 | Date16 Dec 2016 | StatusActive |
| European Union | CE/IVDR EUDAMED | Number— | Date— | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- 510(k) Number
- FDA Product Code
- JGS
- Device Class
- Class II
- Regulation
- 21 CFR Part 862.1665
- Advisory Committee
- Clinical Chemistry
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is a reagent for use with the DxC 700 AU Clinical Chemistry Analyzer, designed for in vitro diagnostic measurement of glucose, C-reactive protein (CRP) via latex agglutination, and ion-selective electrode (ISE) analysis of electrolytes. It falls under the category of electrodes, ion-specific and supports automated clinical chemistry testing for biochemical parameters in serum or plasma samples.
The reagent is supplied as part of a consumable kit for use in clinical laboratories, compatible exclusively with the DxC 700 AU analyzer. It is intended for single-use only and requires no sterilization beyond manufacturer-provided packaging. The device has received FDA 510(k) clearance and IVDR conformity, adhering to regulatory standards for in vitro diagnostics. Storage conditions and expiration dates are specified on the packaging.
Other devices from Beckman Coulter, Inc.
Questions
AI-generated answers, 18 Sep 2026
What clinical chemistry parameters does this reagent measure, and how does it perform those measurements?
This reagent is designed for the DxC 700 AU Clinical Chemistry Analyzer to measure glucose levels, C-reactive protein (CRP) via latex agglutination, and electrolytes using ion-selective electrode (ISE) technology. Glucose is quantified biochemically, CRP is detected through latex agglutination (a turbidimetric immunoassay), and electrolytes are analyzed via ISE, which measures ion-specific conductivity in serum or plasma samples.
Is this reagent intended for single-use or reusable applications, and what are the handling requirements?
The reagent is explicitly intended for single-use only and does not require additional sterilization beyond the manufacturer-provided packaging. It is supplied as part of a consumable kit exclusively for the DxC 700 AU analyzer, meaning each unit is designed for one-time use in automated clinical chemistry testing.
How should this reagent be stored, and what information is provided regarding expiration?
Storage conditions and expiration dates are clearly indicated on the packaging. While the exact details (e.g., temperature range, light exposure) are not specified here, the manufacturer’s instructions on the label must be followed to ensure stability and accuracy. Always verify the expiration date before use to maintain regulatory compliance and test reliability.
What regulatory pathways has this reagent undergone, and which standards does it comply with?
This reagent has received FDA 510(k) clearance under the Traditional pathway (K161837) and IVDR conformity, adhering to EU regulatory standards for in vitro diagnostics. The submission was reviewed by the FDA’s Clinical Chemistry (CH) Advisory Committee and classified under product code JGS, reflecting its role in automated biochemical analysis. Compliance ensures its suitability for clinical laboratory use in the U.S. and EU markets.