Skip to content

Isolation Sleeve Model 347-01

by Intermedics, Inc. 510(k)

Active United States

510(k) K790099

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK790099 Date24 Jan 1979ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Isolation Sleeve Model 347-01 is a sterile, single-use barrier device designed to maintain aseptic conditions during the implantation of implantable pacemaker pulse generators. It provides a protective enclosure to prevent contamination of the device and surrounding surgical field, ensuring sterile handling throughout the procedure.

This device is intended for use in sterile operating room environments and is supplied as a single-use item. It is classified as a Class III medical device under FDA regulations (870.3610) and has received Traditional 510(k) clearance via the Cardiovascular Advisory Committee. The sleeve must be stored in its original packaging until use and is not intended for reuse or reprocessing.

Other devices from Intermedics, Inc.

See all devices from Intermedics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the Isolation Sleeve Model 347-01 during pacemaker surgery?

    The Isolation Sleeve Model 347-01 is designed as a sterile, single-use barrier to maintain aseptic conditions during the implantation of implantable pacemaker pulse generators. It creates a protective enclosure around the device and surgical field to prevent contamination, ensuring sterile handling throughout the procedure.

  • Is the Isolation Sleeve Model 347-01 reusable, or is it intended for single-use only?

    The Isolation Sleeve Model 347-01 is explicitly intended for single-use only. It is not designed for reuse or reprocessing, and must be discarded after a single procedure to maintain sterility and prevent contamination.

  • How should the Isolation Sleeve Model 347-01 be stored before use?

    The sleeve must be stored in its original packaging until the time of use. This ensures sterility and integrity of the barrier until deployment in a sterile operating room environment.

  • What regulatory pathway was followed for FDA clearance of the Isolation Sleeve Model 347-01?

    The Isolation Sleeve Model 347-01 received Traditional 510(k) clearance through the Cardiovascular Advisory Committee, with a decision of Substantially Equivalent (SESE). It is classified as a Class III medical device under FDA regulations (870.3610).