ivWatch (400 +3 more) - Patient Cable
by Ivwatch, LLC
510(k) K192385
Active
Valid until
Not listed
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE 510(k) | NumberK192385 | Date2 Jul 2020 | StatusActive |
| European Union | CE/MDD EUDAMED | Number— | Date— | StatusActive |
| European Union | CE/MDR EUDAMED | Number— | Date— | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- 510(k) Number
- FDA Product Code
- PMS
- Models / Variants
- Patient Cable
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5725
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The ivWatch Model 400 is a Peripheral Intravenous (PIV) Infiltration Monitor, designed to detect and alert clinicians to potential infiltration during intravenous therapy. This device continuously monitors fluid administration to reduce complications such as tissue damage or infection by providing real-time feedback on infusion integrity.
The system comprises the ivWatch Model 400, paired with an Extension Module, SmartTouch Sensor, and Patient Cable for connectivity. Supplied as a reusable device with single-use sensors, it operates in general hospital settings and complies with FDA 510(k) clearance under the Medical Devices Directive (MDD) and Medical Device Regulation (MDR). Storage and handling follow manufacturer guidelines to maintain sensor functionality and device performance.
Other devices from Ivwatch, LLC
Questions
AI-generated answers, 18 Sep 2026
What clinical setting is the ivWatch Model 400 intended for, and how does it help reduce complications during IV therapy?
The ivWatch Model 400 is designed for use in general hospital settings, where it continuously monitors peripheral intravenous (PIV) infusions to detect potential infiltration. By providing real-time feedback on infusion integrity, it helps clinicians prevent complications like tissue damage or infection, which can occur if fluid leaks into surrounding tissues.
Is the ivWatch Model 400 itself reusable, or are there single-use components that need replacement after each patient?
The ivWatch Model 400 device itself is reusable, but it requires single-use sensors (the SmartTouch Sensor and Patient Cable) for each patient. These disposable components ensure accurate monitoring and maintain hygiene standards, while the core device can be reused across multiple patients.
What accessories are included with the ivWatch Model 400, and how do they work together?
The system includes the ivWatch Model 400 monitor, an Extension Module (for connectivity), a SmartTouch Sensor (attached to the IV line), and a Patient Cable (to link the sensor to the monitor). The sensor detects changes in fluid flow or resistance, sending real-time data via the cable and extension module to the monitor, which then alerts clinicians if infiltration is detected.
How should the ivWatch Model 400 and its sensors be stored to ensure proper functionality?
The manufacturer provides specific storage and handling guidelines to maintain sensor functionality and device performance. While exact instructions aren’t detailed here, proper storage typically involves keeping the reusable device in a clean, dry environment and ensuring single-use sensors are stored according to their packaging to prevent contamination or damage before use.
What regulatory pathways does the ivWatch Model 400 follow, and how does that affect its use in hospitals?
The ivWatch Model 400 has received FDA 510(k) clearance under the Medical Devices Directive (MDD) and Medical Device Regulation (MDR), confirming it meets U.S. and EU safety standards for Class II medical devices. This clearance allows hospitals to use it for monitoring PIV infiltration in compliance with regulatory requirements, ensuring its reliability and traceability in clinical settings.