JuggerKnot® 912035
Ref 912035
JuggerKnot 912035 is an orthopaedic implantation sleeve (EU MDD Class I; FDA Class II; FDA product code MBI, Fastener, fixation, nondegradable, soft tissue) made by Biomet Orthopedics, Inc., registered in EUDAMED on 20 Oct 2026 (Basic UDI-DI B-00887868511752), cleared under FDA 510(k) K150768 on 4 Sep 2015 (1 earlier submission) and listed in FDA GUDID since 17 Dec 2021 (UDI-DI 00887868511752), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868511752 00887868511752 | Date20 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868511752 | Date17 Dec 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK150768 | Date4 Sep 2015 | StatusActive |
Official records
- EUDAMED public site B-00887868511752
- AccessGUDID record 00887868511752
- FDA 510(k) database K150768
- FDA 510(k) database K110145
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-00887868511752 registered 20 Oct 2026 Active
- FDA 510(k) K150768 decided 4 Sep 2015 Active
- FDA GUDID UDI-DI 00887868511752 listed 17 Dec 2021 Listed
Recalls
-
- Terminated Z-3252-2018
Expiration date incorrectly listed on the label
-
- Terminated Z-1828-2016
Insufficient seal strength on sterile barrier packaging. The seal could be jeopardized causing the sterile barrier to be compromised and the product could become nonsterile. If the product becomes non-sterile and is used or implanted, it may lead to an infection.
-
- Terminated Z-3109-2011
The device packaging was punctured by the device, resulting in loss of implant sterility.
Timeline
- Cleared FDA 510(k) K110145
- Recall initiated FDA recalls Z-3109-2011
- Cleared FDA 510(k) K150768
- Recall initiated FDA recalls Z-1828-2016
- Recall initiated FDA recalls Z-3252-2018
- Listed FDA GUDID 00887868511752
- Registered EUDAMED B-00887868511752
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- JuggerKnot®
- Generic name
- Orthopaedic implantation sleeve, reusable
- Device name
- SM JK 1_4 and 1_5 Reusable 4Prong End Guide
- Model / Ref / Catalog
- 912035
- Primary DI / UDI-DI
- 00887868511752
- Basic UDI-DI
- B-00887868511752
- FDA product code
- MBI
- EMDN code
- L091199 Orthopaedic prosthetics instruments, reusable - other
- GMDN term
- Orthopaedic implantation sleeve, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 888.3040
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER.
- Resolve Modular Revision Stem 1112-4521-RC by UNITED ORTHOPEDIC CORP.
- U1 Hip System 1201-2122-RB by UNITED ORTHOPEDIC CORP.
- Big Size Trial JR030616 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- RECLAIM 2975-29-105 by DePuy Ireland UC
- Sizer for Eccentric Reverse Metaphysis 04.01.10.0914 by Medacta International SA
- Patient Orient Dev - Pre-op 900020106 by ENZTEC LIMITED
- Quintex® SC434R by Aesculap AG
- HIP Instruments 01.18.10.410 by Medacta International SA
- NexGen® 5987-06 00-5987-006-00 by Zimmer, Inc.