by Medical Research Laboratories, Inc.

510(k) K021168

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)ST Traditional NumberK021168 Date26 Jun 2002DecidedStatusActive

Recalls

7 recalls · FDA

    • Terminated Z-1656-2009 FDA Unclassified (pre-2012) initiated 24 Apr 2009

    Possible for users to misunderstand signals. The original product labeling told users that a flashing low battery indicator signals that the battery is low and requires changing soon. If a user experiences a flashing low battery status indicator and does not understand that the device can continue to be used, the user might choose not to continue operating the device, thereby causing therapy to

    • Terminated Z-1389-2009 FDA Unclassified (pre-2012) initiated 26 Feb 2009

    Issue #1: AED 10 displayed a "Do Not Use" symbol as a result of a blown F1 fuse. Issue #2: AED 10 models that incorporate a spring connector with the speaker experienced intermittent electrical connection to the circuit board causing a loss of voice prompts.

    • Terminated Z-1007-2009 FDA Unclassified (pre-2012) initiated 15 Dec 2008

    Potential for device to deliver less than the programmed energy.

    • Terminated Z-1006-2009 FDA Unclassified (pre-2012) initiated 15 Dec 2008

    Reliability issues - potential to shock a non shockable rhythm or not shocking a shockable rhythm;

    • Terminated Z-1005-2009 FDA Unclassified (pre-2012) initiated 15 Dec 2008

    Potential for device to shut down prematurely under certain circumstances.

    • Terminated Z-0129-2008 FDA Unclassified (pre-2012) initiated 26 Oct 2007

    Failure to Deliver Shock; a defective capacitor may cause the delay or non-delivery of the defibrillating shock which may result in failure to resuscitate the patient

    • Terminated Z-0918-04 FDA Unclassified (pre-2012) initiated 26 Apr 2004 on shared 510(k) K021168

    A faulty component has been identified which could result in an intermittent shock button (button #3) failure on the AED10 defibrillator.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MKJ
Device Class
Class III
Regulation
21 CFR Part 870.5310
Advisory Committee
Cardiovascular
FDA Decision
ST

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Jump Start, Model 970300 is an Automated External Defibrillator (Non-Wearable), designed to deliver electrical shocks to restore normal heart rhythm in patients experiencing sudden cardiac arrest. This device is intended for use by trained personnel in emergency settings to provide life-saving intervention when a patient’s heart is in a life-threatening arrhythmia, such as ventricular fibrillation or pulseless ventricular tachycardia.

The Jump Start, Model 970300 is supplied as a reusable medical device and is classified under FDA regulation 870.5310 as an Automated External Defibrillator (Non-Wearable), falling under product code MKJ. It is intended for use in clinical and pre-hospital emergency settings, adhering to FDA 510(k) clearance (K021168) and subject to tracking under Substantially Equivalent status. The device is not indicated for MRI use and must be stored and maintained according to manufacturer guidelines to ensure proper functionality.

Other devices from Medical Research Laboratories, Inc.

See all devices from Medical Research Laboratories, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of life-threatening heart rhythms is the Jump Start Model 970300 designed to treat?

    The Jump Start Model 970300 is specifically designed to deliver electrical shocks to restore normal heart rhythm in patients experiencing sudden cardiac arrest due to life-threatening arrhythmias such as ventricular fibrillation or pulseless ventricular tachycardia. It is intended for use by trained personnel in emergency settings to provide immediate intervention.

  • Is the Jump Start Model 970300 a single-use or reusable device?

    The Jump Start Model 970300 is a reusable medical device. It is not intended for single-use and must be maintained and stored according to the manufacturer’s guidelines to ensure proper functionality for repeated emergency use.

  • What regulatory pathway was followed for FDA clearance of this device?

    The Jump Start Model 970300 received FDA clearance through a 510(k) submission (K021168) under the Traditional 510(k) Review pathway, with a decision of Substantially Equivalent (ST) and subject to tracking. It falls under FDA regulation 870.5310 and is classified as an Automated External Defibrillator (Non-Wearable) with product code MKJ.

  • Can this device be used in an MRI environment?

    No, the Jump Start Model 970300 is not indicated for MRI use. It must be stored and operated in non-MRI environments to avoid interference or safety risks.

  • What settings is this device approved for use in?

    The Jump Start Model 970300 is intended for use in clinical and pre-hospital emergency settings, such as hospitals, ambulances, and other locations where trained personnel may respond to sudden cardiac arrest. It is not approved for home use or non-emergency settings.