K-Defib/Pace Radiolucent Adult Electrode, Model KRT-60

by Katecho LLC

510(k) K991007

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK991007 Date23 Aug 1999ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MKJ
FDA applicant
Katecho, Inc.
Device Class
Class III
Regulation
21 CFR Part 870.5310
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The K-Defib/Pace Radiolucent Adult Electrode, Model KRT-60, is a defibrillation and pacing electrode designed for use with automated external defibrillators (non-wearable). It is intended for delivering electrical shocks to the heart during cardiac arrest and facilitating temporary pacing to restore normal rhythm.

This single-use, radiolucent electrode is supplied sterile and is intended for emergency cardiac resuscitation in clinical and pre-hospital settings. It is classified as a Class III device under FDA regulations (870.5310) and has received FDA 510(k) clearance as substantially equivalent. The device is not MRI-safe and must be stored in a dry, protected environment until use.

Other devices from Katecho LLC

See all devices from Katecho LLC →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical scenarios is this electrode specifically designed to address in emergency cardiac resuscitation?

    This electrode is designed for delivering defibrillation shocks and temporary pacing to restore a normal heart rhythm during cardiac arrest. It is intended for use with automated external defibrillators (non-wearable) in both clinical settings (like hospitals) and pre-hospital environments (such as ambulances or emergency response sites). Its dual functionality supports both defibrillation (shock delivery) and pacing (temporary electrical stimulation of the heart) to address life-threatening arrhythmias.

  • Is this electrode reusable, or is it meant for single-use only? How does that affect its sterility?

    The KRT-60 is explicitly labeled as a single-use device, meaning it is intended for one-time use only. Because of this, it is supplied sterile to ensure patient safety during emergency cardiac resuscitation. Reuse is not recommended or supported by the manufacturer, as it could compromise sterility and increase infection risks.

  • What storage conditions are required to maintain the electrode’s integrity before use?

    The electrode must be stored in a dry, protected environment until use. This prevents moisture damage, which could affect its performance or sterility. Since it is radiolucent (visible under X-ray), it should also be stored away from sources of radiation to avoid potential degradation.

  • Can this electrode be used in patients who require imaging (e.g., X-ray or CT scans) during resuscitation?

    No, this electrode is radiolucent, meaning it allows X-rays to pass through, but it is not MRI-safe. While it can be used during X-ray or CT imaging, it should not be used in MRI environments due to potential risks from magnetic fields. Always verify compatibility with imaging equipment before use.

  • How do I confirm this electrode is compatible with my defibrillator before use?

    The KRT-60 is designed specifically for automated external defibrillators (non-wearable) and has received FDA 510(k) clearance as substantially equivalent to predicate devices. To confirm compatibility, check your defibrillator’s manufacturer guidelines or contact their technical support. Since it is a Class III device, it should be used only with devices explicitly approved for its intended purpose—never assume compatibility without verification.