← Back to catalogue

Kittykat II

FDA UDI

Class II (US FDA UDI)

by Avinger, Inc.

Identity

Trade Name
Kittykat II FDA UDI
Generic Name
Mechanical atherectomy system catheter, peripheral FDA UDI
Device Name
"Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance. The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire. Kittycat 2 is intended to create a channel in totally occluded peripheral vessels. The device may also be used to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. " FDA UDI
Model / Reference
E550 FDA UDI
Description
"Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance. The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire. Kittycat 2 is intended to create a channel in totally occluded peripheral vessels. The device may also be used to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. " FDA UDI

Identifiers

Catalog Number
E550 FDA UDI
Primary DI / UDI-DI
00851354004059 FDA UDI
510(k) Number
K120273 FDA UDI
FDA Product Code
DQY FDA UDI
GMDN Term
Mechanical atherectomy system catheter, peripheral FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
870.1250 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

Yes

FDA UDI
Sterilization Method
Radiation Sterilization FDA UDI

Category: Mechanical atherectomy system catheter, peripheral

Kittykat II by Avinger, Inc. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Mechanical atherectomy system catheter, peripheral.

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Avinger, Inc.

Sources (1)

  • FDA UDI 0375f0d8-7af8-47b3-8ec3-3c1ded1ec23a 36 fields · synced May 30, 2026