Kodak Directview Cr Cassette/Gp/15 X 30 Cm, Catalog# 8418253

by Eastman Kodak Company

510(k) K040378

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK040378 Date24 May 2004ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
IXA
Device Class
Class II
Regulation
21 CFR Part 892.1850
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Cassette, Radiographic Film (per FDA nomenclature), designed for computed radiography (CR) imaging. It houses a storage phosphor screen that captures latent images from X-ray exposure, enabling digital conversion via a laser scanner for diagnostic radiology applications. The cassette is intended for general radiology and dental panoramic imaging, providing a reusable platform for high-resolution radiographic studies.

The Kodak DirectView CR Cassette GP 15 x 30 cm is supplied as a reusable device, requiring manual cleaning and handling per manufacturer guidelines. It is not sterile and must be processed in a controlled radiology environment. The cassette adheres to FDA Class II regulatory standards, with a 510K clearance under the Radiology advisory committee (K040378). Dimensions (15 x 30 cm) and catalog reference (#8418253) ensure compatibility with Kodak’s CR scanner systems.

Other devices from Eastman Kodak Company

See all devices from Eastman Kodak Company →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Is this cassette designed for single-use or reusable applications, and what maintenance is required?

    This cassette is explicitly designed for reusable applications in computed radiography (CR) imaging. Since it houses a storage phosphor screen, it must be manually cleaned and handled according to the manufacturer’s guidelines to ensure proper function and image quality. It is not sterile, so it should only be used in a controlled radiology environment where contamination risks are managed.

  • What are the key dimensions and compatibility considerations for this cassette, and how does it integrate with Kodak’s systems?

    The cassette measures 15 cm by 30 cm, making it suitable for general radiology and dental panoramic imaging. It is specifically designed for compatibility with Kodak’s CR scanner systems, ensuring seamless digital conversion of X-ray exposures captured by its storage phosphor screen. The catalog number 8418253 helps identify the correct model for ordering and integration.

  • How does this device differ from traditional radiographic film cassettes, and what imaging modalities does it support?

    Unlike traditional radiographic film cassettes, this Kodak DirectView CR Cassette uses a storage phosphor screen to capture latent images digitally, eliminating the need for chemical processing. It supports computed radiography (CR) imaging for general radiology and dental panoramic studies, providing high-resolution diagnostic outputs via laser scanning—unlike conventional film-based systems.

  • What regulatory pathway was followed for this device, and what does the FDA’s classification mean for its use?

    This device followed the FDA’s 510(k) Traditional pathway, classified as Class II under the Radiology advisory committee (K040378). The