Skip to content

KURZ CLIP PISTON MVP - 0.6mm

by Heinz Kurz GmbH Medizintechnik

510(k) K042503

Active European Union and United States

CE MDD 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK042503 Date1 Oct 2004ClearedStatusActive
European UnionCE/MDD EUDAMED Number— Date—StatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

510(k) Number
FDA Product Code
ETA
Models / Variants
0.6mm
Device Class
Class II
Regulation
21 CFR Part 874.3495
Advisory Committee
Ear, Nose, Throat
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Kurz Clip Piston MVP is a Replacement Ossicular Prosthesis, Total, designed to restore conductive hearing loss by replacing missing or damaged ossicles in the middle ear. Constructed for secure fixation, it facilitates sound transmission from the tympanic membrane to the inner ear, improving auditory function in patients with ossicular chain discontinuity.

This device is supplied as a reusable surgical implant, intended for use in otologic procedures under sterile conditions. It is classified as a Class II medical device under FDA regulations and complies with the Medical Device Directive (MDD). The two included models (0.4 mm and 0.6 mm) accommodate varying anatomical requirements, and the prosthesis must be handled with sterile instruments prior to implantation. No MRI safety information is specified.

Other devices from Heinz Kurz GmbH Medizintechnik

See all devices from Heinz Kurz GmbH Medizintechnik →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What are the key differences between the 0.4 mm and 0.6 mm models of the Kurz Clip Piston MVP, and how do they address anatomical variations in patients?

    The Kurz Clip Piston MVP comes in two sizes—0.4 mm and 0.6 mm—to accommodate different anatomical requirements in the middle ear. The 0.4 mm model is designed for smaller ossicular gaps or patients with less space between the tympanic membrane and inner ear, while the 0.6 mm model provides a wider prosthesis for larger anatomical gaps. This variability ensures a secure fit and optimal sound transmission regardless of the patient’s specific ossicular chain discontinuity.

  • How should the Kurz Clip Piston MVP be prepared and handled before surgical implantation to ensure sterility?

    The Kurz Clip Piston MVP is intended for reusable surgical use but must be handled under sterile conditions prior to implantation. It should be sterilized according to standard medical device protocols and only used with sterile instruments during the procedure to prevent contamination. The device is not pre-sterilized in its packaging, so proper sterilization and aseptic technique are critical before use.

  • Are there any specific storage requirements for the Kurz Clip Piston MVP, and how should it be preserved between uses?

    Since the Kurz Clip Piston MVP is a reusable implant, it must be stored in a clean, dry environment to prevent damage or contamination between uses. After sterilization, it should be kept in a sealed, sterile packaging or container until ready for surgical use. The manufacturer’s instructions for sterilization and storage should be followed to maintain its integrity and functionality.

  • What regulatory pathways does the Kurz Clip Piston MVP follow, and which advisory committee oversees its classification?

    The Kurz Clip Piston MVP follows the FDA’s 510(k) Traditional pathway and is classified as Substantially Equivalent (SESE) under the Ear, Nose, and Throat (ENT) specialty. It was reviewed by the Ear, Nose, and Throat (EN) Advisory Committee and is also compliant with the Medical Device Directive (MDD) in Europe. The device’s classification as Class II under FDA regulations reflects its role as a critical implant for restoring conductive hearing loss.