Skip to content

Kyphon Inflatable Bone Tamp

by Kyphon, Inc. 510(k)

Active United States

510(k) K981251

Overview

The Kyphon Inflatable Bone Tamp is a surgical instrument for orthopedic procedures used to reduce fractures or create voids in cancellous bone. It consists of a double-lumen catheter with an inflatable distal component and radiopaque marker bands.

This device is supplied as a single-use instrument and is used in surgical settings. It is authorized under FDA 510(k) clearance with product code HRX and is designed to withstand higher forces during inflation for fracture reduction procedures.

AI-generated from registry data, 24 Sep 2026.Not verified by deviCERTS or the manufacturer

Regulatory status

as of 27 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK981251 Date2 Jul 1998ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

3 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-2389-2020 FDA Class II initiated 24 Apr 2020
    • Terminated Z-2390-2020 FDA Class II initiated 24 Apr 2020
    • Terminated Z-2391-2020 FDA Class II initiated 24 Apr 2020

    Product may not maintain its setting characteristics for the labeled shelf-life duration. Use may lead to longer time for product to set at the time of implantation which may increase the required surgical and anesthesia time for the patient. If the device seeps or creeps from its intended position prior to setting and creates incomplete void or gap filling, possible longer-term health consequences could include incomplete bone formation or lack of bone formation, delayed union, or nonunion.

Specification

510(k)

510(k) Number
FDA Product Code
HRX
Device Class
Class II
Regulation
21 CFR Part 888.1100
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Other devices from Kyphon, Inc.

See all devices from Kyphon, Inc. →

Questions

  • What is the Kyphon Inflatable Bone Tamp used for?

    The Kyphon Inflatable Bone Tamp is a surgical instrument designed for orthopedic procedures to reduce fractures or create voids in cancellous bone. It features a double-lumen catheter with an inflatable distal component and radiopaque marker bands.

  • Is the Kyphon Inflatable Bone Tamp reusable or single-use?

    The Kyphon Inflatable Bone Tamp is supplied as a single-use instrument and is intended for use in surgical settings only. It should not be reused on multiple patients due to sterility and structural integrity concerns.

  • What are the key features of the Kyphon Inflatable Bone Tamp?

    The device consists of a double-lumen catheter with an inflatable distal component and radiopaque marker bands. It is designed to withstand higher forces during inflation for fracture reduction procedures, making it suitable for various orthopedic applications.

  • What is the regulatory status of the Kyphon Inflatable Bone Tamp?

    The Kyphon Inflatable Bone Tamp is authorized under FDA 510(k) clearance with product code HRX. It received traditional clearance on July 2, 1998, and is classified as substantially equivalent to predicate devices in the orthopedic category.