Skip to content

L3-12-D

by GE Medical Systems CO. Ltd

Ref H48062AAModel 5437242

L3-12-D (H48062AA) is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II) made by GE Medical Systems CO. Ltd, registered in EUDAMED on 20 Mar 2025 (Basic UDI-DI 8406821BUG00315H8), cleared under FDA 510(k) K160182 on 26 Feb 2016 and listed in FDA GUDID since 15 Jul 2016 (UDI-DI 00840682105064), active as of 7 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K160182

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00315H8 Basic UDI-DI 00840682105064UDI-DIDate20 Mar 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682105064 UDI-DI Date15 Jul 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK160182 Date26 Feb 2016DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 27 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00315H8 registered 20 Mar 2025 Active
  • FDA 510(k) K160182 decided 26 Feb 2016 Active
  • FDA GUDID UDI-DI 00840682105064 listed 15 Jul 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-1964-2019 FDA Class II initiated 2 Jul 2019

    Potential for a transducer mis-alignment in certain transvaginal probes.

Timeline

4 dated events

  1. Cleared FDA 510(k) K160182
  2. Listed FDA GUDID 00840682105064
  3. Recall initiated FDA recalls Z-1964-2019
  4. Registered EUDAMED 8406821BUG00315H8

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Extracorporeal ultrasound imaging transducer, hand-held
Model / reference
5437242 EUDAMED
H48062AA EUDAMED
L3-12-D GUDID
Primary DI / UDI-DI
00840682105064
Basic UDI-DI
8406821BUG00315H8
Direct marketing DI
00840682105064
510(k) Number
FDA product code
IYO, IYN, ITX
EMDN code
Z110402010101 Two–dimensional linear–array transcutaneous ultrasound probes
GMDN term
Extracorporeal ultrasound imaging transducer, hand-held
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1560, 892.1550, 892.1570
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
5437242
H48062AA
GUDID
L3-12-D
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CN-MF-000001856
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under TWO–DIMENSIONAL LINEAR–ARRAY TRANSCUTANEOUS ULTRASOUND PROBES.

Other devices from GE Medical Systems CO. Ltd

See all devices from GE Medical Systems CO. Ltd →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)