Laserdish Poly Unipolar Ventri Lead W/Trail Tines

by Telectronics Pacing Systems, Inc.

510(k) K904741

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK904741 Date8 Jan 1991ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, specifically a unipolar ventricular lead designed for cardiac pacing applications. It is constructed with a poly material and features trailing tines to enhance fixation within the heart’s ventricular chamber, ensuring stable electrode placement for reliable pacing stimuli delivery.

The Laserdish Poly Unipolar Ventricular Lead with Trail Tines is intended for single-use implantation in cardiac pacing procedures. Supplied sterile and classified under 21 CFR 870.3680, it is regulated as a Class III device and cleared via FDA 510(k) (K904741). No additional sterilization or reprocessing is required post-implantation, and its design adheres to cardiovascular medical device standards.

Other devices from Telectronics Pacing Systems, Inc.

See all devices from Telectronics Pacing Systems, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Is this lead designed for reuse after implantation, or is it intended for single-use only?

    This device is explicitly intended for single-use implantation only. The manufacturer states it is supplied sterile and does not require additional sterilization or reprocessing post-implantation, confirming it is not meant to be reused.

  • What materials is the lead constructed from, and how does that affect its use?

    The lead is constructed from a poly material, which refers to a polyurethane-based composition. This material is chosen for its durability, biocompatibility, and ability to provide stable fixation within the ventricular chamber, ensuring reliable pacing stimuli delivery over time.

  • What specific features of this lead help ensure stable placement in the heart?

    The lead includes trailing tines, which are designed to enhance fixation within the heart’s ventricular chamber. These tines help anchor the electrode securely, reducing the risk of displacement and ensuring consistent pacing performance.

  • How is this device regulated, and what does that mean for its use in clinical settings?

    This device is classified as a Class III medical device under 21 CFR 870.3680 and has been cleared via the FDA 510(k) pathway (K904741). This means it undergoes rigorous review by the FDA’s Cardiovascular (CV) advisory committee to ensure safety and effectiveness for its intended use in cardiac pacing procedures.

  • What storage or handling precautions should be taken with this lead before implantation?

    Since the lead is supplied sterile, it should be stored in its original packaging until use to maintain sterility. The manufacturer does not specify additional handling requirements beyond standard sterile medical device protocols, so proper aseptic techniques should be followed during implantation.