LD-Oxy D001
LD-Oxy D001 is a pulse oximeter (FDA Class II; FDA product code MWI, Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)) made by LD Technology, cleared under FDA 510(k) K160956 on 6 Jul 2016 and listed in FDA GUDID since 16 Jan 2019 (UDI-DI B322D0011), active as of 23 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | NumberB322D0011 | Date16 Jan 2019 | StatusListed |
| United States | FDA 510(k)SESE | NumberK160956 | Date6 Jul 2016 | StatusActive |
Official records
- FDA 510(k) database K160956
From the FDA record
- Device description
- To spot check or monitor Oxygen saturation of arterial hemoglobin (SpO2%) and pulse rate. To analyze the pulse waveform (Photoelectrical Plethysmography or PP) provided by the oximeter. It only provides mathematical analyses of the input of the SpO2 measurement. To analyze the basic rhythms of the NN or RR intervals in heart rate, both in the time domain and in the frequency domain (short time 5 minutes). It only provides mathematical analysis of the input of the heart rate variability. The mathematical analysis of Photoelectrical Plethysmography and HRV ARE NOT intended use for diagnosis. The software provides a visual alarm for the values of the heart rate and/or SpO2 percent out of the normal range and for the bad quality signal transmission. The data are stored in PC in the Backup system of the LD-Oxi software. The device is intended use only for adult subjects (> 20 years old) This Oximeter is intended to be used in spot-checking (5 minutes). The device is intended use in licensed practitioner’s office This device is no intended to be used at home, in hospital or out-of-hospital transport The device is not intended use in support life and not for continuously monitoring The system will be use by practitioner.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K160956 decided 6 Jul 2016 Active
- FDA GUDID UDI-DI B322D0011 listed 16 Jan 2019 Listed
Timeline
- Cleared FDA 510(k) K160956
- Listed FDA GUDID B322D0011
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- LD-Oxy
- Generic name
- Pulse oximeter, line-powered
- Model / reference
- D001
- Primary DI / UDI-DI
- B322D0011
- 510(k) Number
- FDA product code
- MWI
- GMDN term
- Pulse oximeter, line-powered
- Device class
- Class II
- Regulation number
- 870.2300
- GUDID distribution status
- In Commercial Distribution