Legion 71431917 is a knee femur prosthesis trial (FDA Class II; FDA product code JWH) made by Smith & Nephew, Inc., cleared under FDA 510(k) K162775 on 13 Jan 2017 (1 earlier submission) and listed in FDA GUDID since 17 Dec 2021 (UDI-DI 00885556537398), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

9 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00885556537398 UDI-DI Date17 Dec 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK162775 Date13 Jan 2017DecidedStatusActive

Official records

From the FDA record

Device description
LEGION REVISION HINGE OFFSET COUPLER TRIAL BOW 6MM
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K162775 decided 13 Jan 2017 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00885556537398 listed 17 Dec 2021 Listed

Recalls

9 recalls · FDA

    • Terminated Z-1105-2018 FDA Class II initiated 1 Feb 2018 on shared 510(k) K081111

    The screws package with devices within lot 14AAP6352A were 5 MM instead of 10MM and are too short to be used with the Legion HK Distal Wedge Size 5.

  • 2 recalls, same reason

    • Terminated Z-2625-2017 FDA Class II initiated 30 May 2017
    • Terminated Z-2624-2017 FDA Class II initiated 30 May 2017

    The incorrect Loctite adhesive was used to assemble the impactor heads.

  • 6 recalls, same reason

    • Terminated Z-2090-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111
    • Terminated Z-2093-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111
    • Terminated Z-2095-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111
    • Terminated Z-2094-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111
    • Terminated Z-2092-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111
    • Terminated Z-2091-2016 FDA Class II initiated 26 May 2016 on shared 510(k) K081111

    The surface inside of the femoral component, where cement is applied for adhesion, is below specification.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-2093-2016
  2. Recall initiated FDA recalls Z-2095-2016
  3. Recall initiated FDA recalls Z-2094-2016
  4. Recall initiated FDA recalls Z-2092-2016
  5. Recall initiated FDA recalls Z-2091-2016
  6. Cleared FDA 510(k) K162775
  7. Recall initiated FDA recalls Z-2625-2017
  8. Recall initiated FDA recalls Z-2624-2017
  9. Recall initiated FDA recalls Z-1105-2018
  10. Listed FDA GUDID 00885556537398

2 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Legion
Generic name
Knee femur prosthesis trial, reusable
Model / Ref / Catalog
71431917
Description
LEGION REVISION HINGE OFFSET COUPLER TRIAL BOW 6MM
Primary DI / UDI-DI
00885556537398
510(k) Number
FDA product code
JWH
GMDN term
Knee femur prosthesis trial, reusable
Device class
Class II
Regulation number
888.3560
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices in this category

Other devices filed under Knee femur prosthesis trial, reusable.

Other devices from Smith & Nephew, Inc.

See all devices from Smith & Nephew, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)