Legion E0016032-6
Legion E0016032-6 is a bone punch (FDA Class II; FDA product code HRY, Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer) made by Smith & Nephew, Inc., cleared under FDA 510(k) K121393 on 7 Aug 2012 and listed in FDA GUDID since 25 May 2018 (UDI-DI 00885556719879), active as of 23 Oct 2026.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00885556719879 | Date25 May 2018 | StatusListed |
| United States | FDA 510(k)SESE | NumberK121393 | Date7 Aug 2012 | StatusActive |
Official records
- AccessGUDID record 00885556719879
- FDA 510(k) database K121393
From the FDA record
- Device description
- MODULAR FIN PUNCH SZ. 3-4 RIGHT
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K121393 decided 7 Aug 2012 Active
- FDA GUDID UDI-DI 00885556719879 listed 25 May 2018 Listed
Recalls
-
- Ongoing Z-0878-2020
Multiple lots of LEGION AP Femoral Cutting Blocks were manufactured with an oversize green plunger hole and therefore do not meet their design specifications.
-
- Terminated Z-0200-2019
One lot of the Legion AP femoral cutting block, size 6, was manufactured with an oversized spring.
-
- Terminated Z-2163-2018
One lot of GENESIS II 13 mm tibial punches are 2 mm smaller than specification.
-
- Terminated Z-1902-2018
A single lot of GENESIS II FEMORAL FIVE DEGREE VALGUS BUSHING due to a laser mark labeling error. The left valgus bushing was incorrectly laser marked as right and vice versa.
Timeline
- Cleared FDA 510(k) K121393
- Recall initiated FDA recalls Z-1902-2018
- Recall initiated FDA recalls Z-2163-2018
- Listed FDA GUDID 00885556719879
- Recall initiated FDA recalls Z-0200-2019
- Recall initiated FDA recalls Z-0878-2020
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Legion
- Generic name
- Bone punch, reusable
- Model / Ref / Catalog
- E0016032-6
- Primary DI / UDI-DI
- 00885556719879
- 510(k) Number
- FDA product code
- HRY
- GMDN term
- Bone punch, reusable
- Device class
- Class II
- Regulation number
- 888.3530
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code HRY (PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER).
- PHYSICA LMC 6536.50.220 by Limacorporate
- PHYSICA LMC 6537.50.410 by Limacorporate
- P.C.A. TOTAL KNEE STEMMED TIBIA PROSTH by Howmedica Corp.
- MODIFIED SYNATOMIC VARIABLE FIT TIBIAL PLATEAU by Depuy, Inc.
- RESTORIS 111540 by MAKO Surgical Corp.
- DePuy Contour Unicompartmental Knee Prosthesis by DEPUY ORTHOPAEDICS, INC.
- UC-PLUS Solution Unicondylar Knee System by Plus Orthopedics
- SIGMA High Performance Partial Knee System by DePuy Ireland UC
- Unicondylar Fiber Metal Knee by Zimmer, Inc.
- Platform TCCK Total Knee by Biomet, Inc.