# Leksell Stereotactic System 1040153

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/leksell-stereotactic-system-1040153>
- Manufacturer: [Elekta Solutions AB](https://devicerts.com/manufacturers/elekta-solutions-ab) (FDA registration: Sweden)
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: HAW
- EMDN: Z12100601 STEREOTACTIC NEUROSURGERY SYSTEMS
- GMDN: Neurological stereotactic surgery system (32568)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 073402015BUDI000000020PB · UDI-DI 07340201502594 · registered 2026-10-21 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 07340201502594 · listed 2025-02-12 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K152558 · decision 2016-03-02 · decision SESE · status: Active · from GUDID

## Recalls

- Z-0227-2025 · Class I · ongoing · initiated 2024-09-25: Elekta has become aware that Disposable Biopsy Needles can contain some microscopic debris on the inside of the biopsy needle. The material in the debris is stainless steel, same material as the biopsy needle. No debris has been found on the outer parts of the biopsy needles.
- Z-1397-2024 · Class I · ongoing · initiated 2024-03-15: Elekta has become aware that Disposable Biopsy Needles (911933) from one batch (837838839) can contain some microscopic debris on the inside of the biopsy needle. The material in the debris is stainless steel, same material as the biopsy needle. No debris has been found on the outer parts of the biopsy needles. The sterility of the biopsy needles has not been affected. This issue has been reported from one site.
- Z-1309-2023 · Class II · ongoing · initiated 2023-03-01: The incorrect IFU was distributed with the devices.

## Identity

- Trade name: DISPOSABLE INSERTS 4 PCS [EUDAMED]; Leksell Stereotactic System [FDA GUDID (AccessGUDID)]
- Generic name: Neurological stereotactic surgery system [FDA GUDID (AccessGUDID)]
- Model / reference: Disposable inserts [EUDAMED]; 1040300 [EUDAMED]; 1040153 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 07340201502594 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 073402015BUDI000000020PB [EUDAMED]
- 510(k) Number: K152558 [FDA GUDID (AccessGUDID)]
- FDA product code: HAW [FDA GUDID (AccessGUDID)]
- EMDN code: Z12100601 [EUDAMED]
- GMDN term: Neurological stereotactic surgery system (32568) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 882.4560 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- Sterilisation method: Radiation Sterilization [FDA GUDID (AccessGUDID)]
- MRI safety: MR Conditional [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED]; Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Leksell Stereotactic System 1040153, Elekta Solutions AB. deviCERTS medical device catalogue. https://devicerts.com/devices/leksell-stereotactic-system-1040153 (data as of 2026-11-25).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-24
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/leksell-stereotactic-system-1040153.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/leksell-stereotactic-system-1040153
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.