Skip to content

Leksell Stereotactic System 1040343

by Elekta Solutions AB

Part of a family of 22 devices: see the family page

Ref 1040343Model Fixation Screws 20mm-110mm

Leksell Stereotactic System 1040343 is a neurological stereotactic surgery system (EU MDR Class IIa; FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Elekta Solutions AB, registered in EUDAMED on 6 Oct 2026 (Basic UDI-DI 073402015BUDI000000009PP), cleared under FDA 510(k) K152558 on 2 Mar 2016 and listed in FDA GUDID since 21 Aug 2025 (UDI-DI 07340201502716), active as of 24 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K152558

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number073402015BUDI000000009PP Basic UDI-DI 07340201502716UDI-DIDate6 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number07340201502716 UDI-DI Date21 Aug 2025ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK152558 Date2 Mar 2016DecidedStatusActive

Official records

From the FDA record

Device description
FIXATION SCREW 45 MM, TITANIUM
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 073402015BUDI000000009PP registered 6 Oct 2026 Active
  • FDA 510(k) K152558 decided 2 Mar 2016 Active
  • FDA GUDID UDI-DI 07340201502716 listed 21 Aug 2025 Listed

Recalls

3 recalls · 3 ongoing · FDA

    • Ongoing Z-0227-2025 FDA Class I initiated 25 Sep 2024

    Elekta has become aware that Disposable Biopsy Needles can contain some microscopic debris on the inside of the biopsy needle. The material in the debris is stainless steel, same material as the biopsy needle. No debris has been found on the outer parts of the biopsy needles.

    • Ongoing Z-1397-2024 FDA Class I initiated 15 Mar 2024

    Elekta has become aware that Disposable Biopsy Needles (911933) from one batch (837838839) can contain some microscopic debris on the inside of the biopsy needle. The material in the debris is stainless steel, same material as the biopsy needle. No debris has been found on the outer parts of the biopsy needles. The sterility of the biopsy needles has not been affected. This issue has been reported from one site.

    • Ongoing Z-1309-2023 FDA Class II initiated 1 Mar 2023

    The incorrect IFU was distributed with the devices.

Timeline

6 dated events

  1. Cleared FDA 510(k) K152558
  2. Recall initiated FDA recalls Z-1309-2023
  3. Recall initiated FDA recalls Z-1397-2024
  4. Recall initiated FDA recalls Z-0227-2025
  5. Listed FDA GUDID 07340201502716
  6. Registered EUDAMED 073402015BUDI000000009PP

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Fixation Screw 45mm Titanium EUDAMED
Leksell Stereotactic System GUDID
Generic name
Neurological stereotactic surgery system
Model / reference
1040343, Fixation Screws 20mm-110mm
Primary DI / UDI-DI
07340201502716
Basic UDI-DI
073402015BUDI000000009PP
510(k) Number
FDA product code
HAW
EMDN code
Z12100601 Stereotactic neurosurgery systems
GMDN term
Neurological stereotactic surgery system
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
882.4560
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Conditional
Size
Length — 45.0 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under STEREOTACTIC NEUROSURGERY INSTRUMENTS.

Other devices from Elekta Solutions AB

See all devices from Elekta Solutions AB →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (21, all answered No)