Skip to content

LetsGetChecked ImPress IMPRS

by Privapath Diagnostics Limited

LetsGetChecked ImPress IMPRS is a manual blood lancing device (FDA Class II; FDA product code FMK, Single Use Only Blood Lancet With An Integral Sharps Injury Prevention Feature) made by Privapath Diagnostics Limited, cleared under FDA 510(k) K242680 on 13 Jan 2025 and listed in FDA GUDID since 15 Apr 2026 (UDI-DI 00810111410847), active as of 22 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

510(k) K242680

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00810111410847 UDI-DI Date15 Apr 2026ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESU from GUDID Traditional NumberK242680 Date13 Jan 2025DecidedStatusActive

Official records

From the FDA record

Device description
The LetsGetChecked lmPress is a single-use blood lancing tool equipped with an integral sharps injury prevention feature. It is intended for use by health care professionals in producing capillary whole blood samples from the upper arm. To use the device, the user first removes the device tabs to expose the two internally contained lancets. The plastic strip liner is then removed, exposing a layer of medical adhesive. The device is then placed on the upper arm. Activation occurs when the device is compressed against the arm, causing two contact-activated lancets to puncture the skin. The lancets automatically retract to a safe position, preventing sharps injury and re-activation. The device operates solely through mechanical means. During activation, the device generates a vacuum against the skin, which facilitates the emergence of microliter quantities of capillary blood from the puncture site.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K242680 decided 13 Jan 2025 Active
  • FDA GUDID UDI-DI 00810111410847 listed 15 Apr 2026 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K242680
  2. Listed FDA GUDID 00810111410847

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
LetsGetChecked ImPress
Generic name
Manual blood lancing device, single-use
Model / reference
IMPRS
Primary DI / UDI-DI
00810111410847
510(k) Number
FDA product code
FMK
GMDN term
Manual blood lancing device, single-use
Device class
Class II
Regulation number
878.4850
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code FMK (Single Use Only Blood Lancet With An Integral Sharps Injury Prevention Feature).

Other devices from Privapath Diagnostics Limited

See all devices from Privapath Diagnostics Limited →

Properties

  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (11, all answered No)