# Li 2 LM4005

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/li-2-lm4005>
- Manufacturer: [Randox Laboratories, Ltd.](https://devicerts.com/manufacturers/randox-laboratories-ltd)
- Device class: Class II (US FDA)
- FDA product code: NDW
- GMDN: Lithium therapeutic drug monitoring IVD, reagent (55409)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 05055273209143 · listed 2016-09-16 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K050374 · decision 2005-06-15 · decision SESE · status: Active · from GUDID

## Recalls

- Z-0104-2023 · Class II · ongoing · initiated 2022-09-19: Potential for falsely elevated LITH\_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially affecting treatment efficacy.
- Z-0105-2023 · Class II · ongoing · initiated 2022-09-19: Potential for falsely elevated LITH\_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially affecting treatment efficacy.
- Z-0931-2022 · Class II · ongoing · initiated 2022-02-09: Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.
- Z-2430-2020 · Class II · terminated · initiated 2020-06-05: Calibration errors have been observed with the Total and Direct Bilirubin assays when using Chemistry Calibrator lot 534177 for ADVIA Chemistry and lot 534179 for Atellica CH.
- Z-0589-2017 · Class II · terminated · initiated 2016-10-07 · matched through shared submission K050374, may concern other models: Siemens has confirmed that the DBIL\_2 Assigned Calibrator Values (ACV) currently assigned to the affected lots may cause, on average, a positive proportional bias of approximately 41% on patient samples compared to the reference method for Direct Bilirubin measurement.
- Z-0365-2014 · Class II · terminated · initiated 2013-09-24 · matched through shared submission K050374, may concern other models: Siemens Healthcare Diagnostics is conducting a field correction for Siemens Chemistry Calibrator Lots 090445B and 090445C on the ADVIA 1200, 1650, 1800, and 2400 Chemistry Systems. The System Specific Values (SSVs) for the Direct Bilirubin Assay (DBIL\_2) have been reassigned for these lots. Siemens has determined that the DBIL\_2 SSVs currently assigned to these lots may cause an average shift of

## Identity

- Trade name: Li 2 [FDA GUDID (AccessGUDID)]
- Generic name: Lithium therapeutic drug monitoring IVD, reagent [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: LM4005 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 05055273209143 [FDA GUDID (AccessGUDID)]
- 510(k) Number: K050374 [FDA GUDID (AccessGUDID)]
- FDA product code: NDW [FDA GUDID (AccessGUDID)]
- GMDN term: Lithium therapeutic drug monitoring IVD, reagent (55409) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 862.3560 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Convenience kit: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Li 2 LM4005, Randox Laboratories, Ltd. deviCERTS medical device catalogue. https://devicerts.com/devices/li-2-lm4005 (data as of 2026-11-25).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/li-2-lm4005.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/li-2-lm4005
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.