Skip to content

Licox® IP1P

by Integra LifeSciences Switzerland Sàrl

Licox® IP1P is a Class II device made by Integra LifeSciences Switzerland Sàrl, cleared under FDA 510(k) K040235 on 20 Apr 2004 and listed in FDA GUDID since 4 Aug 2016 (UDI-DI 10381780250319), active as of 23 Oct 2026. 12 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

12 closed

Documents

510(k) K040235

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10381780250319 UDI-DI Date4 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK040235 Date20 Apr 2004DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K040235 decided 20 Apr 2004 Active
  • FDA GUDID UDI-DI 10381780250319 listed 4 Aug 2016 Listed

Recalls

12 recalls · FDA

    • Terminated Z-0831-2015 FDA Class II initiated 7 Nov 2014

    Due to a complaint, it was determined that multiple lots of Licox catheters manufactured since October 29, 2013 contained a smart card which was programmed with an inaccurate lkN2 value.

  • 9 recalls, same reason

    • Terminated Z-0061-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0056-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0062-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0063-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0060-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0057-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0055-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0054-2014 FDA Class II initiated 11 Jun 2013
    • Terminated Z-0059-2014 FDA Class II initiated 11 Jun 2013

    Integra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.

    • Terminated Z-0161-2011 FDA Unclassified (pre-2012) initiated 15 Sep 2010

    Incorrect expiration date - The outer boxes of the IP2P Licox Complete Kit for Cerebral Pressure, Temperature and ICP Monitoring Probes, Lot 250210A are labeled with an incorrect shelf life date (10 months too long).

    • Terminated Z-1422-2010 FDA Unclassified (pre-2012) initiated 18 Feb 2010

    One probe that had failed a product release test was inadvertently packaged and released into inventory in Integra's distribution center.

Timeline

14 dated events

  1. Recall initiated FDA recalls Z-0056-2014
  2. Recall initiated FDA recalls Z-0062-2014
  3. Recall initiated FDA recalls Z-0063-2014
  4. Recall initiated FDA recalls Z-0060-2014
  5. Recall initiated FDA recalls Z-0057-2014
  6. Recall initiated FDA recalls Z-0055-2014
  7. Recall initiated FDA recalls Z-0054-2014
  8. Recall initiated FDA recalls Z-0059-2014
  9. Recall initiated FDA recalls Z-0831-2015
  10. Listed FDA GUDID 10381780250319

4 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Licox®
Generic name
Intracerebral sensor catheter, short-term
Model / Ref / Catalog
IP1P
Primary DI / UDI-DI
10381780250319
FDA product code
GWM
GMDN term
Intracerebral sensor catheter, short-term
Device class
Class II
Regulation number
882.1620
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code GWM (DEVICE, MONITORING, INTRACRANIAL PRESSURE).

Other devices from Integra LifeSciences Switzerland Sàrl

See all devices from Integra LifeSciences Switzerland Sàrl →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (8, all answered No)